Bently 106M1081-01 15小卡新款 Universal AC Power Input Module

106M1081‑01 is the universal AC power input small‑card (PIM) for Bently Nevada 3500 machinery protection rack, the new‑generation half‑height rear mating card, must work together with power supply main card 106M1079‑01, cannot run independently. It receives wide‑range AC mains power input, implements input filtering, surge suppression and over‑current protection, feeds processed AC power to 106M1079‑01 power supply unit for DC conversion, then distributes multi‑rail DC power to all modules inside 3500 rack. Installs on left‑hand dedicated half‑height slot of 3500 rack. Supports dual‑module redundant power configuration, hot‑swappable under redundant power setup, available as new‑surplus or refurbished spare parts. Mismatched PIM and PSU main card will cause rack power‑on failure.

Email:2735429704@qq.com
Phone:+86 19316626421

Description

Hardware & Electrical Specifications

‑ Manufacturer: Bently Nevada (Baker Hughes) ‑ Compatible System: 3500 machinery protection system, 3500/15 universal AC power subsystem ‑ Functional Type: Universal AC Power Input Module (PIM, half‑height small card) ‑ Mandatory Mating Unit: 106M1079‑01 (universal AC power supply main card) ‑ AC Input Range: 85‑264 VAC, frequency 47‑63 Hz ‑ Max Power Capacity: 120 W full rack power supply capability ‑ Protection: Input over‑current, surge, over‑voltage and reverse‑transient protection ‑ Indicators: Front‑panel OK status LED for power‑input health diagnosis ‑ Connectors: Screw‑terminal block for AC mains input; internal edge‑card connector mates with 106M1079‑01 main power card ‑ Mounting: Half‑height slot installation on the left dedicated position of 3500 rack ‑ PCB Finish: Conformal coated for ISA‑S71.04 G3 harsh power‑plant cabinet environment ‑ Hot‑swap: Hot‑swappable only under redundant dual‑power configuration. Cut off AC source for single‑supply rack before replacement

Environmental Specifications

‑ Operating Temperature: ‑40 °C ~ +70 °C, power derating at high ambient temperature ‑ Storage Temperature: ‑40 °C ~ +85 °C ‑ Relative Humidity: 5%‑95 % non‑condensing ‑ Vibration & Shock: Complies with API‑670 and power‑industry cabinet EMC transient requirements

Mechanical Data

‑ Weight: approx 0.34 kgNEX Instru… ‑ Form‑factor: Half‑height small‑card for 3500 rack

Core Functions

  1. AC power front‑end gateway: Accepts site wide‑range AC mains input, performs filtering and surge protection, delivers conditioned AC power to 106M1079‑01 power supply main card.
  2. Redundancy support: Supports dual‑PIM+dual‑PSU N+1 redundant power architecture to improve 3500 rack system availability.
  3. Input‑side fault protection: Isolates AC‑side surge and over‑current faults, avoids damaging downstream power‑conversion main card and other monitoring modules.
  4. Visual health diagnosis: OK LED quickly indicates AC input power and PIM module operational status for field maintenance.
  5. Rack power subsystem cooperation: Works with 106M1079‑01 to generate ±5 V, ±15 V, 24 VDC multi‑rail power for all vibration‑monitoring and protection cards inside 3500 rack.

Installation, Replacement & Critical Warnings

  1. For non‑redundant single‑power rack, fully de‑energize upstream AC input before replacement. Hot‑swap is only allowed when redundant power is configured.
  2. Must pair with matching 106M1079‑01 universal AC power main card; legacy HV‑AC / LV‑AC power units are incompatible with this PIM, cannot be mixed‑used.
  3. Torque AC input screw terminals to specified torque value; loose terminals produce overheating and intermittent rack power drop‑out.
  4. After installation, check OK LED status, verify 3500 rack boots normally, complete module configuration download via 3500 Rack Configuration software.
  5. Common failure mode: AC‑side electrical surge damage to input circuit. Investigate site AC power quality and check upstream fuse when PIM OK LED goes off and whole rack loses power.

Reviews