Description
‑ Power Supply: Powered by REG216 rack back‑plane bus (5 VDC, 24 VDC)
‑ Power Consumption: ≤ 12 W
‑ Mechanical Structure: 6U Eurocard rack‑mount plug‑in board, metal front panel, back‑plane parallel bus connector, front‑panel memory‑card slot
‑ On‑board Resources: 32‑bit main CPU core, program EPROM, setting‑parameter EEPROM, runtime RAM, gold‑capacitor buffered event‑log RAM, real‑time clock circuit, B448C parallel back‑plane bus interface, self‑diagnosis logic
‑ Communication Interface: Internal B448C parallel back‑plane bus; front‑panel galvanic‑isolated service serial port for local commissioning PC
‑ Galvanic Isolation: Front‑panel service serial port is electrically isolated from system internal logic bus
‑ Interfaces: Front‑panel service serial connector, memory‑card slot, back‑plane system bus connector
‑ Status LED Indicators: Power, Run, Module Fault, System‑alarm LEDs
‑ Weight: Approx 0.50 kg
‑ Executes complete generator‑transformer protection algorithms, interlock‑logic and blocking‑condition judgment.
‑ Reads multi‑channel analogue sampled data from 216EA62 series and binary‑input status from digital I/O modules via B448C parallel back‑plane bus.
‑ Generates protection trip and interlock commands, transmits control instructions to output modules such as 216DB61, 216NG62A.
‑ Manages protection setting‑parameter database, stores fault event records and disturbance waveforms, provides accurate millisecond‑level time‑stamp for each event.
‑ Uploads measured values, alarm and event logs to upper‑level SCADA via 216MB66 communication module. Supports local parameter download, event reading and disturbance‑data access via front‑panel service port. Memory‑card slot supports firmware upgrade as well as parameter backup‑restore.
‑ Comprehensive hardware self‑diagnosis: detects power‑supply abnormality, memory check‑sum error, firmware failure, back‑plane bus communication error and internal circuit fault, and reports fault status to system.
‑ All protection‑function parameters are configured by CAP2/316 commissioning software.
‑ Cannot operate independently without REG216 rack back‑plane, matched I/O modules and auxiliary power supply. HESG324442R13E and HESG324442R112F are variant part‑numbers for 216VC62a; pin‑compatible within 216VC62a hardware family, not interchangeable with other REG216 plug‑in boards.
‑ Continuously monitors CPU runtime status, memory integrity, back‑plane bus communication and module internal hardware health. Detected faults activate fault LED and suspend protection‑logic execution.
‑ No local numerical display; measured values, protection events and fault codes are retrieved via upper‑level HMI or local commissioning tool.
‑ Module hardware failure will cause complete outage of all generator‑transformer protection and control logic, trip and interlock functions are fully disabled, bringing severe safety risks for power‑plant generator‑transformer set.
‑ Back‑plane connector: Connect to REG216 B448C parallel back‑plane bus for data exchange with all other plug‑in modules.
‑ Front‑panel service serial port: Connect to commissioning PC for parameter setting, event reading and disturbance‑record access.
‑ Front‑panel memory‑card slot: Used for firmware upgrade and protection‑parameter backup‑restore.
‑ Mounting: Plug‑in installation inside REG216 system rack
‑ Operating Temperature: 0 °C ~ +60 °C
‑ Storage Temperature: −40 °C ~ +85 °C
‑ Relative Humidity: 5‑95 %RH, non‑condensing
‑ Protection Class: IP20 (inside cabinet)
- 216VC62a processor unit (HESG324442R13E / HESG324442R112F)
Complementary parts: REG216 system rack and back‑plane, 216NG63A power‑supply supervision module, 216EA62 analogue‑input unit, digital I/O modules, 216MB66 communication module, field shielded signal cables, CAP2/316 commissioning software.
‑ Power off the whole rack before inserting or removing the processor module. Service‑port wiring shall adopt shielded cables with single‑end shield grounding to suppress electromagnetic interference.
‑ For spare‑part replacement: Verify target full part‑number (HESG324442R13E or HESG324442R112F). After replacement, confirm back‑plane bus identification, download complete protection‑setting parameters, verify protection‑logic execution, event‑recording and self‑diagnosis fault‑reporting function.
‑ Module hardware fault results in total failure of generator‑transformer protection functions.
Generator and main‑transformer protection cabinets in thermal / hydro power plants; ABB REG216 numerical generator‑transformer protection‑control system; industrial spare‑part replacement for different hardware variants.
- Core main‑processor unit for REG216 protection‑control system, undertakes generator‑transformer protection‑algorithm calculation, logic judgment, event‑recording and system management. Two part‑number variants HESG324442R13E / HESG324442R112F belong to 216VC62a family.
- Supports disturbance recording, time‑stamped event logging, parameter storage, firmware upgrade and backup via memory‑card slot.
- Built‑in comprehensive self‑diagnosis covers CPU, memory, firmware and back‑plane bus communication status.
- Front‑panel galvanic‑isolated service serial port for on‑site commissioning and debugging.
- Standard Eurocard rack‑mount mechanical structure, convenient installation and maintenance; pin‑compatible within 216VC62a revision series.


-300x300.jpg)



Reviews
There are no reviews yet.