Description
‑ Power Supply: Powered by REG216 rack back‑plane bus (5 VDC, 24 VDC)
‑ Power Consumption: ≤ 12 W
‑ Mechanical Structure: 6U Eurocard rack‑mount plug‑in board, metal front panel, back‑plane parallel bus connector, front‑panel memory‑card slot
‑ On‑board Resources: Main CPU core, program EPROM, setting‑parameter EEPROM, runtime RAM, event‑log RAM, real‑time clock circuit, B448C parallel back‑plane bus interface, self‑diagnosis logic
‑ Communication Interface: Internal B448C parallel back‑plane bus; front‑panel isolated service serial port for local commissioning tool
‑ Galvanic Isolation: Front‑panel service serial port is electrically isolated from system internal logic bus
‑ Interfaces: Front‑panel service serial connector, memory‑card slot, back‑plane system bus connector
‑ Status LED Indicators: Power, Run, Module Fault, System‑alarm LEDs
‑ Weight: Approx 0.50 kg
‑ Executes full‑range generator‑transformer protection algorithms, interlock‑logic and blocking‑condition judgment.
‑ Reads analogue sampling data from 216EA62 series and binary input status from digital I/O modules via B448C back‑plane bus.
‑ Produces protection trip and interlock commands, transmits control instructions to output modules such as 216DB61, 216NG62A.
‑ Manages protection setting database, stores fault event records, disturbance waveforms and provides accurate time‑stamp for each event.
‑ Exchanges measured values, alarms and event logs with upper‑level SCADA system through 216MB66 communication module. Supports local commissioning, parameter download and event reading via front‑panel service port. Memory‑card slot supports firmware upgrade and parameter backup.
‑ Comprehensive hardware self‑diagnosis: detects power‑supply abnormality, memory check‑sum error, firmware failure, back‑plane bus communication error and internal circuit fault, and reports fault status.
‑ All protection‑function parameters are configured by CAP2/316 commissioning software.
‑ Cannot operate independently without REG216 rack back‑plane, matched I/O modules and auxiliary power supply. Hardware revision E adopts upgraded component solution for improved EMC and temperature adaptability; pin‑compatible with earlier B/C/D revisions. Cannot be directly hardware interchanged with other REG216 plug‑in boards.
‑ Continuously monitors CPU running status, memory integrity, back‑plane bus communication and module internal hardware health. Detected faults activate fault LED and suspend protection‑logic execution.
‑ No local numerical display; measured values, protection events and fault codes are retrieved via upper‑level HMI or local commissioning tool.
‑ Module hardware failure will cause complete outage of all generator‑transformer protection and control logic, trip and interlock functions are fully disabled, bringing severe safety risks for power‑plant generator‑transformer set.
‑ Back‑plane connector: Connect to REG216 B448C parallel back‑plane bus for data exchange with all other plug‑in modules.
‑ Front‑panel service serial port: Connect to commissioning PC for parameter setting, event reading and disturbance‑record access.
‑ Front‑panel memory‑card slot: Used for firmware upgrade and protection‑parameter backup‑restore.
‑ Mounting: Plug‑in installation inside REG216 system rack
‑ Operating Temperature: 0 °C ~ +60 °C
‑ Storage Temperature: −40 °C ~ +85 °C
‑ Relative Humidity: 5‑95 %RH, non‑condensing
‑ Protection Class: IP20 (inside cabinet)
- 216VC62a processor unit (HESG324442R13E)
Complementary parts: REG216 system rack and back‑plane, 216NG63A power‑supply supervision module, 216EA62 analogue‑input unit, digital I/O modules, 216MB66 communication module, field shielded signal cables, CAP2/316 commissioning software.
‑ Power off the whole rack before inserting or removing the processor module. Service‑port wiring shall use shielded cables with single‑end grounding to suppress electromagnetic interference.
‑ For spare‑part replacement: Verify complete part number HESG324442R13E. After replacement, confirm back‑plane bus identification, download complete protection‑setting parameters, verify protection‑logic execution, event‑recording and self‑diagnosis fault‑reporting function.
‑ Module hardware fault results in total failure of generator‑transformer protection functions.
Generator and main‑transformer protection cabinets in thermal / hydro power plants; ABB REG216 numerical generator‑transformer protection‑control system; industrial spare‑part replacement for older hardware revisions.
- Core main‑processor unit for REG216 protection‑control system, undertakes generator‑transformer protection‑algorithm calculation, logic judgment, event‑recording and system management.
- Supports disturbance recording, time‑stamped event logging, parameter storage, firmware upgrade and backup via memory‑card slot.
- Built‑in comprehensive self‑diagnosis covers CPU, memory, firmware and back‑plane bus communication status.
- Front‑panel isolated service serial port for on‑site commissioning and debugging.
- Hardware revision E improves EMC performance and temperature tolerance, pin‑compatible with B/C/D revisions, standard Eurocard rack‑mount structure for easy installation and maintenance.