ABB 500MTM02 1MRK001967-AA Multi‑Function Terminal Module

The 500MTM02 is Eurocard‑format plug‑in multi‑function terminal module for ABB Procontrol P13 power‑plant automation system, hardware variant 1MRK001967‑AA. It is the signal transition bridge between field site cables and internal I/O circuit boards inside the control rack. It provides high‑density external wiring terminals for binary and analog process signals, realizes surge suppression, signal filtering and impedance matching. It cooperates with matched I/O modules to complete signal access and wiring loop fault detection. It has no independent signal acquisition or logic computing capability. Widely applied in thermal‑power and hydro‑power generator‑transformer control cabinets. Not hot‑swappable

Email:2306444920@qq.com
Phone:+86 17759635229

Description

Hardware Electrical Specifications

‑ Power Supply: Powered by Procontrol P13 rack back‑plane bus; field side 24 VDC / analog process signal

‑ Power Consumption: approx 4.2 W

‑ Mechanical Structure: Eurocard plug‑in board for Procontrol P13 rack, metal front panel, back‑plane bus connector, large‑capacity field signal terminal block

‑ On‑board Resources: signal distribution circuit, surge‑suppression protection components, filter circuit, loop‑fault sampling circuit, back‑plane bus interface, module self‑diagnosis unit

‑ Communication Interface: Internal dedicated local back‑plane bus for matched I/O functional module

‑ Galvanic Isolation: Galvanic isolation between field wiring terminals and rack internal logic bus, isolation rating 2500 VAC

‑ Supported Signal Types: binary 24 VDC switch signal, 4‑20 mA analog current signal, 0‑10 V analog voltage signal

‑ Status LED Indicators: Power indicator, Module Fault indicator

‑ Weight: approx 0.88 kg

Main Functions

‑ Provides centralized wiring terminals for matched I/O modules, completes transition connection between field site cables and internal I/O circuit boards.

‑ Built‑in surge‑suppression and filter circuit, restrains surge pulse and high‑frequency interference introduced by field cables, protects internal I/O channel circuits.

‑ Realizes signal distribution and impedance matching for binary and analog process signals.

‑ Supports signal‑loop fault sampling detection, transmits wiring‑loop abnormal status to the paired I/O functional module.

‑ Module self‑diagnosis monitors back‑plane bus connection and power‑supply abnormal state, uploads module‑level fault‑alarm information.

‑ Cannot run independently; must be installed and used together with corresponding I/O functional modules inside Procontrol P13 rack. 1MRK001967‑AA is hardware revision variant of 500MTM02 series; pin‑compatible within 500MTM02 revision family, cannot directly interchange with other types of terminal modules.

Control & Monitoring Function

‑ Continuously monitors module power‑supply and back‑plane bus connection status. Detected faults activate fault LED and send fault word to main processor.

‑ No local numerical display; terminal‑module fault information is read via commissioning software or upper‑level HMI workstation.

‑ Module hardware failure will cause signal‑access abnormality of matched I/O channels; rack internal control‑logic operation keeps normal.

Communication Interfaces

‑ Back‑plane connector: connects to Procontrol P13 internal local bus for signal interaction with matched I/O module.

‑ Field signal terminal block: wiring terminals for field sensors, contact and actuator cables.

Environmental Specifications

‑ Mounting: Plug‑in installation inside Procontrol P13 system rack

‑ Operating Temperature: ‑20 °C ~ +60 °C

‑ Storage Temperature: −40 °C ~ +70 °C

‑ Relative Humidity: 5‑95 %RH, non‑condensing

‑ Protection Class: IP20 (cabinet internal)

System Complementary Components
  1. 500MTM02 multi‑function terminal module (1MRK001967‑AA)
Complementary parts: Procontrol P13 rack and back‑plane, matched I/O functional module, rack power‑supply unit, field shielded signal cables, Procontrol P13 commissioning software.
Installation Notes

‑ Power off the whole rack before inserting or removing this terminal module. Field wiring adopts shielded cables with single‑end shield grounding; strictly separate binary and analog signal wiring.

‑ For spare‑part replacement: Verify complete part number 1MRK001967‑AA, confirm matching with corresponding I/O module. After replacement, confirm back‑plane bus identification, verify signal‑loop access and fault‑reporting function. Mismatched terminal module will result in abnormal signal processing.

‑ Module hardware fault will lead to access failure of associated I/O signal channels.

Typical Application Scenarios

Generator‑transformer control cabinets of thermal / hydro power plants; ABB Procontrol P13 automation system; industrial spare‑part replacement for field‑signal terminal transition unit.

Key Features
  1. Procontrol P13 platform dedicated multi‑function signal terminal module, realizes transition wiring between field cables and internal I/O boards, hardware variant 1MRK001967‑AA.
  2. Built‑in surge‑suppression and filter protection, improves anti‑interference performance under harsh electromagnetic environment of power plant.
  3. Galvanic isolation design between field‑wiring side and rack internal logic circuit.
  4. Cooperates with matched I/O module to implement wiring‑loop fault detection.
  5. Standard Eurocard rack‑mount plug‑in structure, convenient installation and field‑wiring maintenance.