Description
‑ Power Supply: Powered by Procontrol P13 rack back‑plane bus; field side 24 VDC / analog process signal
‑ Power Consumption: approx 4.2 W
‑ Mechanical Structure: Eurocard plug‑in board for Procontrol P13 rack, metal front panel, back‑plane bus connector, large‑capacity field signal terminal block
‑ On‑board Resources: signal distribution circuit, surge‑suppression protection components, filter circuit, loop‑fault sampling circuit, back‑plane bus interface, module self‑diagnosis unit
‑ Communication Interface: Internal dedicated local back‑plane bus for matched I/O functional module
‑ Galvanic Isolation: Galvanic isolation between field wiring terminals and rack internal logic bus, isolation rating 2500 VAC
‑ Supported Signal Types: binary 24 VDC switch signal, 4‑20 mA analog current signal, 0‑10 V analog voltage signal
‑ Status LED Indicators: Power indicator, Module Fault indicator
‑ Weight: approx 0.88 kg
‑ Provides centralized wiring terminals for matched I/O modules, completes transition connection between field site cables and internal I/O circuit boards.
‑ Built‑in surge‑suppression and filter circuit, restrains surge pulse and high‑frequency interference introduced by field cables, protects internal I/O channel circuits.
‑ Realizes signal distribution and impedance matching for binary and analog process signals.
‑ Supports signal‑loop fault sampling detection, transmits wiring‑loop abnormal status to the paired I/O functional module.
‑ Module self‑diagnosis monitors back‑plane bus connection and power‑supply abnormal state, uploads module‑level fault‑alarm information.
‑ Cannot run independently; must be installed and used together with corresponding I/O functional modules inside Procontrol P13 rack. 1MRK001967‑AA is hardware revision variant of 500MTM02 series; pin‑compatible within 500MTM02 revision family, cannot directly interchange with other types of terminal modules.
‑ Continuously monitors module power‑supply and back‑plane bus connection status. Detected faults activate fault LED and send fault word to main processor.
‑ No local numerical display; terminal‑module fault information is read via commissioning software or upper‑level HMI workstation.
‑ Module hardware failure will cause signal‑access abnormality of matched I/O channels; rack internal control‑logic operation keeps normal.
‑ Back‑plane connector: connects to Procontrol P13 internal local bus for signal interaction with matched I/O module.
‑ Field signal terminal block: wiring terminals for field sensors, contact and actuator cables.
‑ Mounting: Plug‑in installation inside Procontrol P13 system rack
‑ Operating Temperature: ‑20 °C ~ +60 °C
‑ Storage Temperature: −40 °C ~ +70 °C
‑ Relative Humidity: 5‑95 %RH, non‑condensing
‑ Protection Class: IP20 (cabinet internal)
- 500MTM02 multi‑function terminal module (1MRK001967‑AA)
Complementary parts: Procontrol P13 rack and back‑plane, matched I/O functional module, rack power‑supply unit, field shielded signal cables, Procontrol P13 commissioning software.
‑ Power off the whole rack before inserting or removing this terminal module. Field wiring adopts shielded cables with single‑end shield grounding; strictly separate binary and analog signal wiring.
‑ For spare‑part replacement: Verify complete part number 1MRK001967‑AA, confirm matching with corresponding I/O module. After replacement, confirm back‑plane bus identification, verify signal‑loop access and fault‑reporting function. Mismatched terminal module will result in abnormal signal processing.
‑ Module hardware fault will lead to access failure of associated I/O signal channels.
Generator‑transformer control cabinets of thermal / hydro power plants; ABB Procontrol P13 automation system; industrial spare‑part replacement for field‑signal terminal transition unit.
- Procontrol P13 platform dedicated multi‑function signal terminal module, realizes transition wiring between field cables and internal I/O boards, hardware variant 1MRK001967‑AA.
- Built‑in surge‑suppression and filter protection, improves anti‑interference performance under harsh electromagnetic environment of power plant.
- Galvanic isolation design between field‑wiring side and rack internal logic circuit.
- Cooperates with matched I/O module to implement wiring‑loop fault detection.
- Standard Eurocard rack‑mount plug‑in structure, convenient installation and field‑wiring maintenance.