ABB CHBX01R 2VAA008575R1 Table Description:CHBX01R, Right‑Side Compact Bus Extender, 2VAA008575R1

CHBX01R (2VAA008575R1) is ABB Symphony Plus SD‑Series right‑side compact horizontal bus extender for HN800 redundant I/O bus. Installed at right end of horizontal I/O row, it provides dual redundant HN800 bus termination for SD‑series I/O modules, paired with CHBX01L left‑side extender. It is active production hardware for critical process DCS applications.

Email:2735429704@qq.com
Phone:+86 19316626421

Description

General Information

表格
Item Specification
Part Number CHBX01R, 2VAA008575R1
Manufacturer ABB
Product Family ABB Ability Symphony Plus DCS, SD‑Series I/O System
Product Type Compact Horizontal Bus Extender (Right‑side) for HN800 redundant I/O bus
Installation DIN‑rail mounting, installed at the right end of horizontal SD‑Series I/O module row, must work together with CHBX01L(left‑side bus extender) to define a complete HN800 I/O segmentABB Abilit….
Power Supply 24 VDC auxiliary power (19.2‑30 VDC), power input is supplied from CHBX01L on the left side of the row via backplane bus.
Lifecycle Status Active product; OEM production, spare‑parts and technical support available.
ESD Handling Requirement Bus interface electronic assembly; anti‑static wrist‑strap and anti‑static workstation required for installation and replacement.

Electrical & Interface Specifications

  • Backplane Interface: Redundant HN800 I/O bus connectors (A‑bus / B‑bus), high‑speed 4 Mbit/s redundant I/O communication bus for SD‑series I/O modulesABB Abilit….
  • Mechanical Bus Interface: Internal row‑bus connector, terminates HN800 differential bus signals for the entire horizontal I/O row segment.
  • Signal Type: Redundant HN800 differential bus signals; no external 24 VDC power input terminals on CHBX01R itself.
  • On‑Board Circuitry: Bus termination circuitry, status LED indicators. No process I/O channels for field sensors/actuatorsABB Abilit….
  • Bus Performance: HN800 bus baud rate 4 Mbit/s, dual redundant A/B bus for fault‑tolerant communication.
  • Power Consumption: Typical 1‑2 W (module self‑consumption only).
  • Operation Limitation: Cannot operate standalone. Must be deployed together with CHBX01L, SD‑series I/O modules and Symphony Plus controller; defines the right‑side physical boundary of one horizontal I/O row segment.
  • Compatibility Matrix

    ‑ Compatible System: ABB Symphony Plus SD‑Series DCS, HN800 redundant I/O bus system

    ‑ Matching Part: CHBX01L (Left‑side compact bus extender 2VAA008574R1)

    ‑ Compatible I/O modules: All SD‑series SD I/O modules

    ‑ Hot‑swap: Not supported; power‑down the I/O row before replacement.

Environmental Specifications

表格
Item Value
Operating Temperature 0 °C ~ +55 °C inside ventilated control cabinet
Storage / Transport Temperature ‑40 °C ~ +85 °C
Relative Humidity 5‑95 % RH, non‑condensing
Compliance & Certifications CE, UL, IEC 61010‑1 industrial automation standard
Protection Class IP20 (module housing); internal circuit IP00
Dimension 125 mm × 45 mm × 110 mm (H×W×D)
Net Weight Approx. 0.20 kg
Conformal Coating Conformal‑coated variant available for harsh corrosive plant environments.
Vibration Resistance Complies with IEC 60068‑2‑6 cabinet vibration criteria.

Main Functions

  1. CHBX01R (2VAA008575R1) is the right‑side compact horizontal bus extender for ABB Symphony Plus SD‑Series HN800 redundant I/O bus. It is mounted at right end of a horizontal I/O row, working together with CHBX01L at left‑end to form one complete I/O bus segmentABB Abilit….
  2. Provides physical termination for dual redundant HN800 A/B I/O bus on the right boundary of the row. It does not accept external 24 VDC power input; power is delivered from CHBX01L through row backplane.
  3. Cooperates with CHBX01L to realize high‑speed redundant HN800 bus communication between Symphony Plus controller and SD‑series field I/O modules; dual‑bus design improves communication reliability for critical power‑plant and process‑control applications.
  4. LED status indicators show HN800 bus operating condition for on‑site inspection.
  5. No analog / digital field I/O channels; it is purely bus termination hardware, does not directly connect to field transmitters or actuatorsABB Abilit….
  6. Typical field failure symptoms

    ‑ Entire horizontal I/O row reports HN800 bus communication fault

    ‑ Redundant bus single‑channel failure alarm

    Common root causes: backplane connector poor contact, bus termination hardware damage.

Typical Applications

  1. New‑project configuration and spare‑part replacement for Symphony Plus SD‑series HN800 I/O station right‑side bus extender.
  2. Power‑plant, pulp‑paper, chemical process DCS control cabinet I/O rack assembly.
  3. Preventive‑maintenance spare‑part inventory for ABB Symphony Plus DCS system.
  4. DCS system retrofit and expansion of SD‑series I/O stations.