Description
‑ Power Supply:Supplied by rack back‑plane 24 VDC;typical power consumption 5.0 W
‑ Mechanical Structure:standard S100 rack plug‑in module;weight approx 0.45 kg
‑ On‑board Resources:serial protocol processing unit, signal driving circuit, data buffer unit, back‑plane bus interface, module self‑diagnosis circuit
‑ Communication Interface:internal back‑plane bus for data exchange with Advant controller;external RS‑232‑C / RS‑485 serial interface
‑ Galvanic Isolation:galvanic isolation between external serial‑port side and control internal logic side, isolation rating 2500 VAC
‑ Core Function:GCOM bus protocol processing, serial‑port protocol conversion, bidirectional data transmission between controller and external equipment
‑ Protection:serial‑port surge‑suppression and ESD protection
‑ Status LED Indicators:Power indicator, Module Fault indicator, communication sending‑receiving status LED
‑ Weight:approx 0.45 kg
‑ Installed in Advant OCS S100 standard rack, communicates with Advant AC410 series controller via rack back‑plane GCOM bus.
‑ Provides isolated RS‑232‑C and RS‑485 external serial channels, completes protocol conversion, realizes bidirectional data exchange between controller and upper‑level monitoring station, field instrument and third‑party equipment.
‑ Built‑in data buffer, adapts to multi‑point serial bus communication scene, reduces data‑loss risk caused by bus conflict.
‑ Module self‑diagnosis monitors back‑plane power‑supply and on‑board hardware status; detects hardware fault and communication abnormality, reports fault information to controller.
‑ Cannot run independently; must cooperate with Advant OCS rack and AC410 series controller. CI543 3BSE010699R1 belongs to dedicated GCOM communication board, cannot be substituted by general‑purpose serial communication modules.
‑ Continuously monitors rack power‑supply and module hardware running state. Fault will activate panel fault LED and report fault alarm word to Advant controller.
‑ No local historical‑data storage; module status and fault codes need to be read through Advant configuration‑monitoring tool.
‑ Module hardware failure will cause loss of GCOM serial communication channel; controller internal logic operation keeps normal, but serial‑port data interaction with external equipment fails.
‑ Back‑plane connector: inserts into S100 rack slot, connects to GCOM internal bus of Advant controller.
‑ External serial terminals: connect communication cables to operation station, field instruments and third‑party devices.
‑ Mounting:insert into Advant OCS S100 standard rack slot
‑ Operating Temperature:‑20 ℃ ~ +60 ℃
‑ Storage Temperature:‑40 ℃ ~ +85 ℃
‑ Relative Humidity:5‑95 %RH, non‑condensing
‑ Protection Class:IP20, cabinet‑internal installation.
- CI543 GCOM communication interface module(3BSE010699R1)
Complementary parts: Advant OCS S100 rack, AC410 series controller, serial communication cables, Advant configuration monitoring tool.
‑ Cut off control cabinet auxiliary power before inserting or replacing this module. Set serial‑port baud rate, data bit, parity bit according to site requirements; parameter mismatch will lead to communication no‑data.
‑ For spare‑part replacement: verify full model CI543 and part‑number 3BSE010699R1; after installation check back‑plane power‑supply, verify bidirectional data interaction between controller and external serial‑devices. Hardware‑version mismatch will bring risk of communication‑parsing abnormality.
‑ Module fault will result in failure of DCS system GCOM serial communication channel.
Petrochemical, power, metallurgy old‑set Advant OCS DCS control cabinets; ABB Advant OCS system maintenance and spare‑part replacement; industrial spare‑part for GCOM bus serial‑communication gateway unit.
- Advant OCS dedicated CI543 GCOM communication interface module (3BSE010699R1), completes protocol conversion and bidirectional data exchange between Advant controller and external serial‑port equipment.
- Isolated RS‑232‑C / RS‑485 dual physical interfaces, adapts to point‑to‑point and multi‑drop‑bus field wiring.
- Serial‑port galvanic‑isolation design, restrains field‑site electromagnetic interference and protects controller internal circuit.
- Built‑in data buffer, improves stability of multi‑node serial‑bus communication.
- Standard S100 rack plug‑in structure, convenient cabinet installation and spare‑part swapping.
- Legacy discontinued DCS spare‑part, only applied for old‑system maintenance and retrofit projects.