Description
General Information
| Item | Specification |
|---|---|
| Part Number | D674A906U01 |
| Manufacturer | ABB |
| Product Family | Electromagnetic Flowmeter Transmitter Insert Cartridge |
| Product Type | Flowmeter electronic insert module with HART communication & local display |
| Installation | Plug‑in cartridge, installed inside ABB electromagnetic flowmeter converter housing |
| Power Supply | 24 VDC loop‑power or external auxiliary power supply |
| Lifecycle Status | Active spare part; available as OEM replacement spare, some variants may be obsolete depending on flowmeter host model |
| ESD Handling Requirement | Precision measurement electronics; anti‑static wrist‑strap and anti‑static workstation required for installation and replacement operations. |
Electrical & Interface Specifications
- Internal Sensor Interface: Input for flow sensor electrode signal and coil excitation drive signal.
- Output Signals: 4‑20 mA analog current output; pulse / frequency output option.
- Communication Protocol: HART 7 digital communication protocol for remote parameter configuration and diagnostic data read‑back.
- Local Man‑Machine Interface: Integrated LCD display and push‑button keypad for on‑site parameter setup, flow value indication and fault checkingABB Group.
- Measuring Performance: Typical measuring accuracy ±0.2 % of measured value; flow velocity measuring range 0.02‑32 m/s.
- On‑Board Circuitry: DSP signal processing unit, excitation drive circuit, HART modem, display driving circuit, self‑diagnosis monitoring circuit.
- Power Consumption: Typical 1.5‑2.5 W.
- Operation Limitation: Cannot operate standalone. Must match corresponding ABB electromagnetic flow sensor; it is the internal electronic core cartridge of flowmeter converter.
- Compatibility Matrix
‑ Compatible Device: ABB series electromagnetic flow sensor assemblies
‑ Mounting: Plug‑in insert cartridge inside converter housing
‑ Hot‑swap: Not supported; power shall be cut off before cartridge replacement.
Environmental Specifications
| Item | Value |
|---|---|
| Operating Temperature | ‑20 °C ~ +70 °C inside flowmeter converter housingABB DCS HE… |
| Storage / Transport Temperature | ‑40 °C ~ +85 °C |
| Relative Humidity | 5 %‑95 % RH, non‑condensing |
| Compliance Standard | CE certification for process automation industry, meets EMC industrial requirements |
| Protection Class | Electronics assembly IP00; overall converter housing achieves IP67 after full assemblyABB DCS HE…. |
| Dimension | 37 mm × 26 mm × 25 mm (cartridge body)ABB DCS HE… |
| Net Weight | Approx. 20 gABB DCS HE… |
| Conformal Coating | Conformal‑coated variant available for corrosive, high‑humidity field environments. |
| Vibration Resistance | Complies with IEC 60068‑2‑6 industrial field vibration criteria. |
Main Functions
- D674A906U01 is the plug‑in electronic cartridge for ABB electromagnetic flowmeter converter. It processes weak induction signals from flow sensor electrodes, calculates flow velocity, volume flow and total flow value, and converts into standard industry output signals.
- Provides 4‑20 mA analog output and pulse output for connection to DCS / PLC control system. Built‑in HART communication realizes remote parameter modification, measurement reading and equipment diagnostic via HART hand‑held communicator.
- Integrated LCD and keypad support local on‑site operation: display real‑time flow rate, accumulated totalizer, set measuring range, configure output parameters and check fault diagnostic information.
- Continuous self‑diagnosis: monitor sensor electrode status, excitation coil condition, internal hardware fault, and report corresponding alarm codes.
- Modular plug‑and‑play design: when flowmeter converter electronics fails, replace this cartridge directly without replacing the whole flow sensor body, reducing maintenance cost and site downtime.
- Typical field failure symptoms
‑ No flow output signal while sensor piping has actual flow
‑ Incorrect / drifting flow measured value
‑ HART communication cannot connect
‑ Local display blank or keypad no response
Common root causes: power supply abnormality, sensor electrode signal circuit damage, HART modem fault, ageing of internal electronic components, moisture ingress inside converter housing.
- Mainly used as maintenance replacement spare‑part for existing electromagnetic flowmeter installations.
Typical Applications
- Spare‑part replacement for internal electronic cartridge of ABB electromagnetic flowmeter converter.
- Process flow measurement maintenance for water‑treatment, chemical, petrochemical, pulp‑paper industry sites.
- Preventive‑maintenance spare‑part inventory for industrial flow measuring points equipped with ABB magnetic flowmeters.
- On‑site refurbishment of old electromagnetic flowmeter converter assemblies.



-300x300.jpg)