Description
Hardware & Electrical Specifications
- Model:DTCC901B
- Part Number:61430001‑FU
- Module Type:Digital Relay Output Module
- Channel quantity:8 channels, each SPDT (NO / NC / COM) dry contact
- Isolation:Every 2 channels form one isolation group, group‑to‑group opto‑isolation; channels to back‑plane bus galvanic isolation
- Rated load voltage:AC 250V;DC 30V
- Continuous rated current per channel:5A resistive load
- Peak short‑time current:10A, duration ≤1s
- Contact mechanical life:≥1 000 000 cycles (resistive load);≥100 000 cycles (inductive load)
- Output response time:≤10 ms (from command to relay action)
- Built‑in fuse:6A /250V per channel, drawer‑type replaceable fuse
- Surge protection:Varistor parallel on each contact (AC275V / DC33V); support external RC snubber circuit for inductive load
- Power supply:24 V DC (‑15% ~ +10%) supplied by rack back‑plane
- Power consumption:max 4.2 W
- Insulation resistance:≥100 MΩ @500 V DC
- Dielectric strength:2.5 kV AC between field side and back‑plane logic side
Environmental Specifications
- Operating temperature:0 ℃ ~ +55 ℃
- Storage temperature:‑20 ℃ ~ +70 ℃
- Relative humidity:5%‑95% non‑condensing
- Protection class:IP20 (module internal, cabinet installation)
- Anti‑interference:meet IEC 61000‑6‑2 industrial EMC standard
- Certifications:CE, UL
Mechanical Data
- Installation:Slot‑in mounting on Advant OCS standard rack, mechanical latch locking
- Terminal type:Screw terminal, suitable for 0.75 mm²‑4 mm² copper wire
- Dimension:120 mm × 110 mm × 45 mm
- Weight:approx 0.35 kg
Main Functions
- 8‑channel SPDT relay output:Each channel provides normally‑open and normally‑closed contacts, flexible for interlock, backup circuit design. Direct drive contactor coil, solenoid valve, local indicator light without extra intermediate relay。
- Contact actual status feedback:The module reads real relay contact position and sends back to DCS controller, realize closed‑loop monitoring “control command‑actual execution status”. Prevent hidden fault that command sent but relay not act.
- Per‑channel self‑diagnosis:Detect fuse blown, output over‑current, internal relay fault. Fault information includes channel number and fault type, uploaded to control system for alarm.
- LED status indication per channel:
- Green ON:contact closed
- Green OFF:contact open
- Red flash:channel fault (fuse blow / relay failure)
- Parameter configurable via Control Builder software:Support output delay setting, fault latch / auto‑reset mode, channel invert logic.
- Group‑wise galvanic isolation:Reduce cross‑channel interference when mixing AC and DC field loads.
- Easy maintenance:Drawer‑type fuses can be replaced without removing whole module from rack.
Installation & Wiring Requirements
- Install into standard Advant OCS rack slot, latch click to lock; back‑plane bus complete power and communication automatically.
- Keep sufficient cabinet ventilation, avoid corrosive gas, conductive dust, strong magnetic field near module.
- For inductive load (solenoid, contactor coil), install external RC absorption circuit on load side to suppress back‑EMF and extend relay service life.
- Strictly follow load voltage & current rating; do not exceed 5A continuous current for each channel.
- Cabinet grounding must comply with industrial control grounding specification to guarantee isolation performance and anti‑interference capability.
- Wiring torque for screw terminals: 0.8‑1.2 N·m.