ABB INNIS21 Network Interface Slave Module

The INNIS21 3BSE008594R1 belongs to ABB Symphony Harmony INFI90 DCS system. It is INFI‑NET ring network slave interface module, used for connecting I/O sub‑rack without local MFP/BRC processor to INFI‑NET dual redundant ring network. It realizes data exchange between remote I/O sub‑rack and main control station over INFI‑NET ring. Field I/O signals collected by sub‑rack I/O modules are transmitted to main‑rack processor through INNIS21 and INFI‑NET ring network. Widely used in power plant, petrochemical and pulp‑paper industry Symphony DCS cabinets. This module only completes network data forwarding, control logic is executed by main station MFP or BRC processor.

Email:2735429704@qq.com
Phone:+86 19316626421

Description

Hardware Electrical Specifications

‑ Power Supply:Power supplied by Harmony rack back‑plane, 5VDC back‑plane logic power supply

‑ Mechanical Structure:Rack plug‑in module for Symphony Harmony rack;overall weight approx 0.36kg

‑ On‑board Resources:INFI‑NET communication controller, back‑plane bus interface circuit, hardware self‑diagnosis circuit, link monitoring circuit.

‑ Communication Interface:INFI‑NET dual‑ring coaxial interface; internal rack back‑plane module bus communicating with local I/O modules in sub‑rack.

‑ Galvanic Isolation:Transformer isolation between INFI‑NET ring network side and sub‑rack back‑plane system side.

‑ Core Function:Sub‑rack INFI‑NET slave network access, data forwarding between sub‑rack local I/O and INFI‑NET ring network, link status monitoring, hardware self‑diagnosis, fault alarm upload to DCS operator station.

‑ Protection:Coaxial port surge and over‑voltage protection.

‑ Status LED Indicators:Ring A communication LED, Ring B communication LED, module run LED, fault LED.

‑ Weight:approx 0.36kg

Main Functions

‑ INNIS21 is dedicated slave network interface for I/O sub‑rack without own station processor. It enables I/O sub‑rack to join INFI‑NET dual redundant ring network, all I/O point data of sub‑rack is transmitted to main control station processor via ring network.

‑ Support Ring A / Ring B dual‑ring redundancy, single ring fault will not affect sub‑rack I/O normal operation. Real‑time monitor ring communication state and sub‑rack back‑plane bus state. When ring break, hardware failure occurs, trigger fault indication and alarm upload.

‑ Installed in I/O sub‑rack slot, communicate with sub‑rack local I/O modules through rack back‑plane bus. Cannot run independently, must work with main station MFP/BRC processor over INFI‑NET ring network.

Difference compared with INIIT13:INIIT13 serves main control station with processor; INNIS21 is for processor‑free pure I/O sub‑rack, realize sub‑rack accessing INFI‑NET ring.
Control & Monitoring Function

‑ Complete data forwarding between sub‑rack local I/O modules and INFI‑NET ring network.

‑ Monitor dual‑ring network link and sub‑rack back‑plane bus status, fault information upload to DCS system.

‑ No independent control logic, all control algorithm runs on main‑station processor.

Signal Interfaces

‑ Back‑plane:Rack internal back‑plane module bus, connect sub‑rack local I/O modules.

‑ External interfaces:INFI‑NET Ring A and Ring B coaxial ring‑network interfaces.

Environmental Specifications

‑ Mounting:Plug‑in installation on Symphony Harmony standard rack

‑ Operating Temperature:‑20 ℃ ~ +60 ℃

‑ Storage Temperature:‑40 ℃ ~ +85 ℃

‑ Relative Humidity:5‑95 %RH, non‑condensing

‑ Pollution degree:Degree 2

‑ Protection Class:IP20, cabinet‑internal installation.

System Complementary Components
  1. INNIS21 network interface slave module(3BSE008594R1)
Complementary parts: Symphony Harmony I/O sub‑rack, INFI‑NET coaxial communication cable, main station IMMFP03 / BRC processor, INIIT13 termination module, system rack power supply, Harmony series I/O modules.
Installation Notes

‑ Insert module into designated network slot of I/O sub‑rack, tighten front‑panel screws to ensure reliable back‑plane connector contact.

‑ Distinguish Ring A and Ring B coaxial interfaces strictly, coaxial connectors must be fastened reliably, avoid poor contact leading to ring‑network abnormal.

‑ Module replacement recommends power‑off operation. After replacement, check dual‑ring LED status, confirm no ring‑break alarm, verify sub‑rack I/O points data upload normally to main control station.

‑ Prevent short‑circuit between coaxial inner conductor and shielding layer to avoid module damage.

Typical Application Scenarios

Power plant, petrochemical, pulp‑and‑paper industry Symphony INFI90 DCS control cabinets; network access spare‑part for processor‑free pure I/O sub‑rack.

Key Features
  1. ABB Symphony Harmony INNIS21 network interface slave module (3BSE008594R1), INFI‑NET ring slave interface for processor‑less I/O sub‑rack.
  2. Dual‑ring Ring A / Ring B redundant access, transformer isolation, suppress external interference entering sub‑rack back‑plane.
  3. Real‑time monitor ring link and sub‑rack bus status, fault LED indication and alarm upload function.
  4. Rack plug‑in structure, cabinet‑internal IP20 application, specially used for pure I/O sub‑rack accessing INFI‑NET ring network.
  5. Only undertake network data forwarding, no local control logic, rely on main station processor for control calculation.
  6. Discontinued legacy DCS spare‑part, used for old‑system maintenance and retrofit projects。

Reviews

There are no reviews yet.

Be the first to review “ABB INNIS21 Network Interface Slave Module”

Your email address will not be published. Required fields are marked *