Description
Hardware & Electrical Specifications
- Model:IS200SPIDG1ABA
- Part Number:IS200SPIDG1ABA
- Module Type:SPID Speed‑Input DSP Interface Board
- Form factor:Single‑slot double‑height 6U VME plug‑in board
- Power supply:+5 V / ±15 V DC supplied by rack backplane, typical power consumption 10 W
- Speed input:Multi‑channel MPU magnetic‑pickup pulse input, max input frequency 50 kHz
- DSP processing:On‑board high‑speed digital signal processor for speed‑value calculation, overspeed & zero‑speed logic
- Backplane interface:Dual 96‑pin P1/P2 VME back‑plane connectors
- Front‑panel connectors:BNC / screw terminals for MPU sensor wiring; test diagnostic port
- PCB treatment:Conformal coated for dust‑moisture‑corrosion resistance
- On‑board protection:Over‑voltage surge suppression, ESD protection, hardware overspeed interlock circuit independent of software
- Compatibility note:Cannot run standalone; must match Mark VI / Mark VIe system firmware revision; TMR system requires three‑board consistency verification; overspeed simulation test mandatory after replacement.
Environmental Specifications
- Operating temperature:‑40 ℃ ~ +70 ℃
- Storage temperature:‑40 ℃ ~ +85 ℃
- Relative humidity:5%‑95% non‑condensing
- Installation location:Turbine control cabinet VME rack
- EMC compliance:IEC 61000‑6‑2
- Certifications:CE
Mechanical Data
- Weight:approx 0.9 kgABB-DCS He…
- Dimension:340 mm × 216 mm × 30 mm
- Handling note:ESD‑sensitive PCB; high‑speed pulse measuring circuit, anti‑static wrist‑strap mandatory during handling
- Recommended wire cross‑section:0.75‑2.5 mm² shielded twisted‑pair copper cable for MPU speed‑sensor wiring
- Terminal tightening torque:0.6‑1.0 N·m
Main Functions
- Receive pulse signals from turbine‑shaft magnetic pickup sensors, condition high‑frequency pulse input signals.
- On‑board DSP computes real‑time shaft rotating‑speed value for turbine governor control loop.
- Hardware overspeed detection, zero‑speed detection; output trip‑request signal for turbine protection logic.
- Exchange speed‑measurement data, fault diagnostic messages with main controller via VME back‑plane bus.
- TMR triple‑redundant mode supports three‑way voting logic to avoid single‑board fault causing false trip.
- On‑board self‑diagnosis: detect MPU sensor open‑circuit / short‑circuit, board power failure, VME‑bus communication abnormality, report fault alarm.
- Front‑panel LED status indication:
- Green LED:Module power‑on normal
- Yellow LED:Pulse‑signal input & VME‑bus communication active
- Red LED:Overspeed condition / MPU loop fault / board hardware fault
Installation & Wiring Requirements
- Cut off rack power supply before replacement. Hot‑swap is forbidden. Strict anti‑static protection when handling PCB board.
- Insert module fully into designated VME rack slot, lock ejector levers to ensure reliable back‑plane connector contact.
- MPU speed‑sensor wiring strictly follow GE Speedtronic wiring manual; speed pulse cables must be shielded twisted‑pair, strictly separated from high‑power cables; connect shielding to dedicated ground terminal.
- Complete protective grounding according to GE Speedtronic system specification.
- After replacement: verify raw pulse input signal, check real‑time speed reading, perform overspeed‑condition simulation test before commissioning.
- Replacement note: TMR redundant system must verify three‑group speed channel consistency; overspeed protection function test is mandatory after swap.