Description
Hardware & Electrical Specifications
- Model:IS200SPROH1AAB
- Part Number:IS200SPROH1AAB, MRP663860
- Module Type:SPRO Secondary‑Protection Terminal Board
- Mounting:DIN‑rail / cabinet panel mounting
- Power supply:+24 V DC auxiliary power supplied by matched I/O pack
- Signal interface:Screw terminal block for field protection wiring; two high‑density ribbon‑cable connectors for I/O pack interconnection
- Isolation:Built‑in isolation transformers, high galvanic isolation for protection signal channels
- Signal type:Backup overspeed trip, vibration trip, low‑oil‑pressure trip, ESD emergency shutdown discrete input signals
- PCB treatment:Conformal coated for dust‑moisture‑corrosion resistance
- On‑board protection:ESD protection, surge suppression, transient absorption circuit for trip‑signal loops
- Compatibility note:Cannot run standalone; must match Mark VI protection I/O pack; TMR system requires three identical SPRO boards; full protection‑loop simulation test mandatory after replacement.
Environmental Specifications
- Operating temperature:‑40 ℃ ~ +70 ℃
- Storage temperature:‑40 ℃ ~ +85 ℃
- Relative humidity:5%‑95% non‑condensing
- Installation location:Turbine control cabinet
- EMC compliance:IEC 61000‑6‑2
- Certifications:CE
Mechanical Data
- Weight:approx 0.55 kg
- Dimension:178 mm × 159 mm × 30 mm
- Handling note:ESD‑sensitive PCB, anti‑static wrist‑strap mandatory during handling
- Recommended wire cross‑section:0.75‑2.5 mm² shielded twisted‑pair copper cable for field protection‑signal wiring
- Terminal tightening torque:0.6‑1.0 N·m
Main Functions
- Screw‑terminal field termination for turbine secondary backup protection signals: backup overspeed trip, vibration trip, low‑oil‑pressure, emergency shutdown ESD contact signals.
- On‑board isolation transformers provide galvanic isolation between field‑side plant wiring and control logic side, eliminate ground‑loop interference for critical safety trip signals.
- Condition protection discrete signals and transmit to matched I/O pack through dual ribbon‑cable interface for turbine protection voting logic processing.
- Suppress surge and transient noise induced by long‑distance field wiring in high‑EMI power‑plant environment.
- On‑board channel self‑diagnosis: detect field‑loop open‑circuit, signal‑chain abnormality, report fault status to turbine main controller.
- On‑board self‑diagnosis: detect terminal‑board auxiliary power loss and ribbon‑cable link failure.
- LED status indication:
- Green LED:Terminal‑board auxiliary power normal
- Yellow LED:Ribbon‑cable link communication active
- Red LED:Field‑protection‑channel fault / link communication loss alarm
Installation & Wiring Requirements
- Cut off rack power supply before replacement. Hot‑swap is forbidden. Strict anti‑static protection when handling PCB board.
- Secure mounting bracket firmly; ensure dual ribbon‑cable connectors fully locked without loose contact.
- Field protection‑signal wiring strictly follow GE Mark VI wiring manual; safety trip signal cables must adopt shielded twisted‑pair, strictly separated from high‑power cables; connect shielding to dedicated ground terminal.
- Complete protective grounding according to GE Speedtronic system specification.
- After replacement: verify ribbon‑cable link status, simulate each protection trip‑signal input, validate turbine trip‑logic response before commissioning.
- Replacement note: For TMR redundant system, three‑set SPRO channel consistency must be verified; full safety‑protection‑loop simulation test is mandatory after swap.