Description
Hardware & Electrical Specifications
- Model:PFEA111‑65
- Part Number:3BSE050090R65
- Module Type:IP65 Enclosed Tension Measuring Amplifier
- Housing:IP65 / NEMA4 metal enclosed housing, wall/machine mountingplcix.com
- Power supply:24 V DC (18‑36 V DC), power consumption 7.5 WABB Group
- Sensor channel:2‑channel load‑cell input; 330 Hz sensor excitation 0.5 A rmsABB Group
- Analog output:0‑10 V, 4‑20 mA configurable
- Communication:No Profibus‑DP(PFEA112 series for Profibus‑DP)
- Display:2×16 character multi‑language LCD with setting keys
- Measuring accuracy:±0.1% full scale
- Galvanic isolation:between sensor side and control logic side
- On‑board protection:overload protection, signal filtering, short‑circuit protection, dust‑water resistant sealed housing
- Compatibility note:Cannot run standalone; match ABB PFCL / PFTL tension sensors, must match host system configuration. Not direct interchangeable with DIN‑rail PFEA111‑20 due to mechanical housing difference.
Environmental Specifications
- Operating temperature:‑10 ℃ ~ +55 ℃
- Storage temperature:‑40 ℃ ~ +70 ℃
- Relative humidity:5%‑95% non‑condensing
- Installation location:Directly mounted on production machinery, field environment
- EMC compliance:IEC 61000‑6‑2
- Certifications:CE, UL61010C
Mechanical Data
- Weight:approx 1.10 kg
- Dimension:220 mm × 145 mm × 80 mm
- Terminals:cable‑gland entry for sensor, power and analog signal cables
- Recommended wire cross‑section:0.75 mm²‑2.5 mm² copper cable for signal terminals
- Terminal tightening torque:0.6‑1.0 N·m
Main Functions
- Supply excitation and acquire measuring signal from dual tension load‑cells.
- Calculate tension value of individual channel, sum(A+B) and difference(A‑B).
- Configurable digital filtering for suppressing mechanical vibration and noise interference.
- Analog output 4‑20 mA / 0‑10 V for PLC / drive closed‑loop tension control.
- Local LCD display for tension value reading, parameter setting and status diagnosis.
- Channel self‑diagnosis: detect sensor break, overload and circuit fault, report alarm status.
- LED status indication:
- Green LED:Power supply normal, unit healthy
- Yellow LED:Measuring signal active
- Red LED:Over‑load / sensor fault / unit hardware fault
Installation & Wiring Requirements
- Cut off power supply before wiring or replacement. Firmly fix PFEA111‑65 on machine mounting base. Hot‑swap is forbidden.
- Install cable glands properly to guarantee IP65 protection grade; connect load‑cell sensor cable, power cable and analog output strictly per wiring drawing; separate sensor weak‑signal cables from high‑power cables to reduce electromagnetic interference.
- Complete protective grounding according to ABB tension‑system specification.
- After replacement, perform load‑cell calibration, set filter parameters and measuring range; verify analog output function before commissioning.
- Replacement note: parameter download and recalibration are required after unit replacement. Cannot directly swap with DIN‑rail PFEA111‑20 because of mechanical housing difference.




-300x300.jpg)
Reviews