Description
Hardware & Electrical Specifications
- Model:PFEA112‑20
- Part Number:3BSE030369R0020
- Module Type:Tension Control Electronics Module
- Mounting:DIN‑rail mounting, IP20 protection grade
- Power supply:24 V DC (18‑36 V DC), power consumption 7.5 WABB Group
- Sensor channel:2‑channel load‑cell input; 330 Hz sensor excitation 0.5 A rmsABB Group
- Analog I/O:configurable analog input, 0‑10 V / 4‑20 mA analog output
- Communication:Profibus‑DP fieldbus interface
- Display:2×16‑character multi‑language LCD with setting keys
- Measuring accuracy:±0.1% full scale
- Control function:integrated PID auto‑tune closed‑loop tension control
- Galvanic isolation:between sensor side and control logic side
- On‑board protection:overload protection, sensor break detection, signal filtering, short‑circuit protection
- Compatibility note:Cannot run standalone; match ABB PFCL / PFTL tension sensors, must match host system configuration.
Environmental Specifications
- Operating temperature:‑10 ℃ ~ +55 ℃
- Storage temperature:‑40 ℃ ~ +70 ℃
- Relative humidity:5%‑95% non‑condensing
- Installation location:Inside industrial control cabinet
- EMC compliance:IEC 61000‑6‑2
- Certifications:CE, UL61010C
Mechanical Data
- Weight:approx 0.45 kg
- Dimension:145 mm × 100 mm × 45 mm
- Terminals:screw terminal blocks for sensor, power, analog signal and Profibus‑DP bus
- Recommended wire cross‑section:0.75 mm²‑2.5 mm² copper cable for signal terminals
- Terminal tightening torque:0.6‑1.0 N·m
Main Functions
- Supply excitation and acquire measuring signal from dual tension load‑cells.
- Calculate tension value of individual channel, sum(A+B) and difference(A‑B).
- Built‑in PID closed‑loop tension control with auto‑tune function, output control signal to drive / brake.
- Configurable digital filtering for suppressing mechanical vibration and site electromagnetic noise.
- Analog input‑output for local signal interconnection with PLC and drive system.
- Local LCD display for tension reading, PID parameter setting and unit status diagnosis.
- Profibus‑DP communication for remote reading tension value, alarm status and parameter download.
- Channel‑level self‑diagnosis: detect sensor break, overload, cable fault, report alarm status.
- LED status indication:
- Green LED:Power supply normal, unit healthy
- Yellow LED:Measuring signal / Profibus‑DP communication active
- Red LED:Over‑load / sensor fault / control‑loop fault / unit hardware fault
Installation & Wiring Requirements
- Cut off power supply before wiring or replacement. Mount PFEA112‑20 firmly on DIN‑rail inside cabinet. Hot‑swap is forbidden.
- Connect load‑cell sensor cable, power cable, analog signal and Profibus‑DP bus cable strictly per wiring drawing; separate weak‑signal sensor cables from high‑power cables to reduce electromagnetic interference.
- Complete protective grounding according to ABB Pressductor tension‑system specification.
- After replacement, perform load‑cell calibration, set PID parameters, complete Profibus‑DP station address configuration; verify measuring, closed‑loop control and bus communication function before commissioning.
- Replacement note: sensor calibration and PID parameter download are mandatory after unit replacement. Cannot directly swap with PFEA111 series, PFEA112 has integrated closed‑loop control function.






Reviews
There are no reviews yet.