Description
Hardware & Electrical Specifications
‑ Manufacturer: ABB ‑ Functional Type: Arc‑Flash Protection Relay ‑ Current Input: 3‑phase AC current inputs from current transformers ‑ Sensor Input: Multi‑channel optical fiber arc‑light sensor interfaces ‑ Operating Principle: Light‑only, current‑only, light + current dual‑condition tripping modes ‑ Trip Reaction Time: Typical 1‑7 ms total detection‑to‑trip output ‑ Auxiliary Power: 24‑250 VAC / 24‑250 VDC wide‑range auxiliary supply ‑ Output Contacts: Multiple high‑speed trip relay outputs, alarm signal contacts ‑ Local Interface: Front‑panel LCD display, push‑button keypad for parameter configuration ‑ Data Logging: Stores arc‑fault event records, fault timestamp and measured current values ‑ Communication: RS485 interface, supports Modbus‑RTU protocol for remote monitoring ‑ Connectors: Screw terminals for CT inputs, auxiliary power, trip/alarm outputs; fiber‑optic ports for arc sensors ‑ Mounting: Switchgear front panel cut‑out mounting ‑ PCB Finish: Conformal coated for harsh switchgear‑cabinet environment
Environmental Specifications
‑ Operating Temperature: ‑20 °C ~ +60 °C ‑ Storage Temperature: ‑40 °C ~ +85 °C ‑ Relative Humidity: 5%‑95 % non‑condensing ‑ EMC: Complies with power‑industry switchgear EMI and transient standards
Mechanical Data
‑ Weight: approx 1.1 kg
Core Functions
- Arc‑flash fault detection: Combines optical arc‑light detection and over‑current condition to identify internal arc faults inside switchgear compartments.
- Ultra‑fast tripping output: Provides high‑speed relay trip signals to upstream circuit‑breakers to limit arc‑energy release and equipment damage.
- Flexible logic configuration: Selectable operating modes: light‑only, current‑only, light‑and‑current dual‑condition interlock trip.
- Fault event recording: Captures fault timestamp, current magnitude and triggered sensor channel for post‑incident analysis.
- Remote supervision: Modbus‑RTU communication uploads fault and alarm status to plant SCADA / DCS system.
Installation, Replacement & Critical Warnings
- De‑energize auxiliary supply, CT secondary circuits and trip‑circuit wiring before replacement. Unit is non‑hot‑swappable. CT secondary circuits present dangerous open‑circuit voltage hazards.
- Verify optical arc‑sensors are correctly routed and fixed inside each switchgear compartment; mis‑positioned sensors result in missed arc‑fault detection.
- Configure light sensitivity threshold and over‑current pickup setting according to switchgear design; overly‑sensitive parameters cause nuisance tripping.
- After installation, perform functional test: simulate arc‑light signal and over‑current condition to validate trip‑relay action.
-
Common failure mode: Degradation of optical‑sensor fiber, surge damage to CT input circuits. Check sensor alignment and fiber integrity when loss‑of‑sensor alarms appear.