Description
System frequency: 50 Hz /60 Hz
Auxiliary supply: 80‑250 V DC / 85‑265 V AC
Total power consumption: ≤35 W
Local HMI: LCD graphic display, configurable LED indicators and operation push‑buttons
Communication interfaces: Ethernet(IEC61850), SPA, RS485 serial port, supports GOOSE messaging
Event & disturbance recording: Sequential‑of‑event log, disturbance recorder, COMTRADE fault waveform storage
Setting groups: Maximum 6 groups of parameter settings
Mounting mode: 19‑inch standard rack‑mount, draw‑out plug‑in chassis
Operating temperature: −25 ℃ ~ +55 ℃
Storage temperature: −40 ℃ ~ +85 ℃
Humidity: 5‑95 %RH non‑condensing
EMC compliance: IEC 60255‑22‑1 /‑22‑2 /‑22‑3
Certifications: CE, UL, IEC 61850, IEC 60255 approval
Realize local & remote control for breakers, disconnectors and earthing switches at bay level. Built‑in select‑before‑operate logic, bay‑level and station‑wide interlock function. Collect binary input signals, monitor trip‑circuit condition and equipment status. Complete analog measurement of voltage, current, power and frequency. Support event sequence recording, fault disturbance recording and parameter management. Exchange data with station control system via multiple communication protocols. Comprehensive hardware self‑diagnosis, detect module faults and upload alarm information. Configuration and maintenance are performed via PCM600 engineering tool.
Difference compared with 1MRK008514‑AA / 1MRK008514‑AB: 1MRK008514‑CB is late‑stage hardware revision; mechanical installation is fully drop‑in compatible; component and surge‑immunity circuit upgraded, better long‑term stability; pay attention to firmware and project version matching after replacement.
Install in 19‑inch standard rack inside substation control cabinet. Standard secondary wiring for binary input and output loops. Auxiliary power supply shall be within rated voltage range. After unit replacement, download complete project configuration file, verify interlock logic, switch control function, point‑to‑point signal test and station‑control communication. Check self‑diagnosis status to confirm no hardware fault alarms.
Bay‑level control for power plant and high‑voltage substation, suitable for feeder bay, transformer bay and bus‑coupler bay. Used for switchgear operation control, status acquisition and data uploading in power grid and industrial power distribution secondary protection systems.
- Relion 650 series late‑revision bay‑level control unit for substation bay‑control application.
- Draw‑out modular hardware, physical drop‑in compatible with AA and AB versions, convenient for on‑site maintenance replacement.
- Upgraded component and surge‑immunity circuit, improved long‑term operation stability for substation environment.
- Powerful interlock logic, select‑before‑operate mechanism to prevent mis‑operation.
- Native IEC 61850 and GOOSE support, adapts to digital substation construction requirements.
- Integrated measurement, event recording and disturbance recording functions, no extra auxiliary equipment required.
- Industrial spare‑part for maintenance and retrofitting of legacy ABB Relion 650‑series bay‑control devices.