Description
CT secondary rated: 1 A /5 A configurable
System frequency: 50 Hz / 60 Hz
Auxiliary supply: 80‑250 V DC / 85‑265 V AC universal power
Total power consumption: ≤28 W
Local HMI: Graphic LCD display, LED status indicators and operation push‑buttons
Communication interfaces: Dual 10/100 Mbps Ethernet, serial RS485; supports PRP/HSR network redundancy, IRIG‑B time synchronization
Fault recording: COMTRADE disturbance waveform storage, sequential‑of‑event log storage
Mounting mode: 19‑inch standard rack‑mount, withdrawable plug‑in unit
Operating temperature: −25 ℃ ~ +55 ℃
Storage temperature: −40 ℃ ~ +85 ℃
Humidity: 5‑95 %RH non‑condensing
EMC compliance: IEC 60255‑22‑1 /‑22‑2 /‑22‑3
Certifications: CE, UL, IEC 60255, IEC 61850 approval
Non‑directional / directional phase overcurrent protection, earth‑fault protection, sensitive earth‑fault protection, thermal overload protection, phase unbalance protection, over‑voltage / under‑voltage protection. Optional auto‑reclosing, fault‑location calculation, arc‑flash detection function. Realize local & remote circuit‑breaker control, bay‑level interlock logic and trip‑circuit supervision. Perform high‑accuracy measurement for current, voltage, active/reactive power, energy and frequency. Sequence‑of‑event logging, disturbance waveform recording and multi‑setting‑group management. Comprehensive hardware self‑diagnosis, detect internal hardware fault and upload alarm status to local HMI and station control system. Configuration and maintenance are completed via PCM600 engineering tool.
Installed in 19‑inch standard rack of substation protection cabinet. Strictly comply with CT polarity for secondary wiring, avoid CT secondary open‑circuit hazard. Auxiliary power supply shall be kept within rated voltage range. After unit replacement, download complete project configuration file, execute protection function test, breaker trip‑close loop test, binary input/output point‑to‑point signal test and station‑control communication verification. Confirm no hardware self‑diagnosis fault alarms.
Medium‑voltage feeder protection for power plants, urban substations and industrial power distribution systems. Applicable for overhead‑line and cable feeder in radial, ring and meshed distribution networks, also can be used as backup protection for transformer and motor bay.
- Relion 615 series compact feeder protection & control IED, withdrawable plug‑in mechanical structure for convenient on‑site maintenance.
- Abundant built‑in protection functions, supports sensitive earth‑fault, auto‑reclosing and feeder fault‑location.
- Native IEC 61850 Ed.2, GOOSE and network redundancy PRP/HSR, adapt to digital substation requirements.
- Integrated measurement, event logging and COMTRADE disturbance recording functions.
- Multiple communication protocol options, compatible with traditional and new‑generation substation automation systems.
- Industrial spare‑part for maintenance and retrofitting of ABB Relion 615‑series feeder‑protection devices.