Description
CT secondary rated: 1 A / 5 A configurable
System frequency: 50 Hz / 60 Hz
Auxiliary supply: 80‑250 V DC / 85‑265 V AC wide‑range power
Total power consumption: ≤25 W
Local HMI: Graphic LCD display, LED status indicators and operation push‑buttons
Communication interfaces: RS485 serial port, LON bus interface
Fault recording: COMTRADE disturbance waveform storage, sequential‑of‑event event log
Mounting mode: 19‑inch standard rack‑mount unit
Operating temperature: −25 ℃ ~ +55 ℃
Storage temperature: −40 ℃ ~ +85 ℃
Humidity: 5‑95 %RH non‑condensing
EMC compliance: IEC 60255‑22‑1 /‑22‑2 /‑22‑3
Certifications: CE, UL, IEC 60255 approval
Non‑directional / directional phase overcurrent multi‑stage protection, earth‑fault protection, sensitive earth‑fault protection, thermal overload protection, phase unbalance and phase‑sequence supervision.
Motor‑oriented protection includes start‑up supervision, locked‑rotor monitoring and anti‑frequent‑start inhibition.
Breaker‑failure protection, configurable auto‑reclosing function.
Realize local & remote circuit‑breaker control, bay‑level interlock logic and trip‑circuit supervision.
True‑RMS high‑accuracy measurement for current, voltage, active/reactive power, energy and frequency.
Event sequence logging, COMTRADE fault disturbance recording and multiple setting‑group management.
User‑configurable programmable logic for custom interlock and alarm functions.
Continuous hardware self‑diagnosis detects internal faults and outputs alarm signals to local HMI and upper‑level station control system.
Configuration and commissioning are completed via CAP501 / CAP505 engineering softwareeero.
Installed in 19‑inch standard rack inside substation protection cabinet. Strictly follow CT/VT polarity for secondary wiring, avoid CT secondary open‑circuit hazard. Auxiliary power supply shall be kept within rated voltage range. After unit replacement, download complete project configuration file. Perform protection‑logic verification test, breaker trip‑close loop test, binary input/output point‑to‑point signal test and communication validation with SCADA system. Confirm no hardware self‑diagnosis fault alarms.
Medium‑voltage incoming‑feeder, outgoing‑feeder protection for power plants, industrial plants and utility distribution substations. Also suitable for medium‑voltage motor protection, can act as backup protection for transformer baysABB Group.
- Legacy multifunction feeder protection relay, compact rack‑mount structure for secondary cabinet installation.
- Comprehensive protection function library, applicable for both distribution feeders and medium‑voltage motor protection occasions.
- Built‑in programmable logic function, flexible to realize custom interlock and alarm logic.
- Integrated true‑RMS measurement, time‑stamped event logging and COMTRADE disturbance recording functions.
- Multiple industrial communication protocols supported for connecting to substation automation systems.
- Discontinued ABB legacy spare‑part, used for maintenance and retrofitting of existing REX521‑series protection devices.