Hardware and Performance Specifications Auxiliary supply: 24 V DC, support 9‑36 V DC wide‑range input Power consumption: ≤15 W Analog channels: multi‑channel galvanic‑isolated analog input for generator voltage, stator current, rotor excitation current and cabinet temperature signals; signal filtering‑conditioning circuit, 16‑bit ADC sampling Binary I/O: multi‑group isolated digital input and output channels for cabinet switch‑status collection and interlock‑alarm signal transmission Communication interfaces: AC800PEC rack internal back‑plane bus Mounting mode: rack plug‑in module for excitation cabinet AC800PEC rack Operating temperature: ‑20 ℃ ~ +70 ℃ Storage temperature: ‑40 ℃ ~ +85 ℃ Humidity: 5‑95 %RH non‑condensing EMC compliance: IEC 61000‑4 series industrial electromagnetic compatibility standards Dimension & weight: approx. 210 × 145 × 50 mm, weight about 1.3 kg Certifications: CE approval
Main Functions Realize isolation filtering and signal conditioning for generator terminal voltage, stator current, rotor excitation‑current analog signals, suppress field electromagnetic interference noise. Complete A/D conversion for excitation‑system measuring analog quantities, transmit sampling data to excitation main‑controller through back‑plane bus. Collect cabinet‑site binary signals: breaker auxiliary contact, cooling‑fan status, cooling‑water flow, cabinet‑door interlock and other switch‑quantity signals. Receive control commands from main‑controller, convert and output binary interlock and alarm signals. Front‑panel LED indicators show channel operating status and fault codes. Hardware self‑diagnosis detects channel abnormal and internal circuit fault, upload fault information to main‑controller. Channel parameter configuration and debugging are finished by UNITROL Configurator and Control Builder M engineering software.
Installation Requirement Plug‑in installation inside AC800PEC rack of excitation cabinet. High‑power cables and weak‑signal sampling cables shall be routed separately, ensure reliable cabinet grounding. Auxiliary 24 V DC power supply must stay within rated working range. After module replacement, confirm hardware suffix version matches original project configuration, download complete excitation project configuration file. Perform analog‑channel calibration, binary‑I/O point‑to‑point test and back‑plane bus communication inspection. This module must match excitation main‑controller and cannot run alone. Different suffix variants of UAD149 series (A0001/A0011/A1501 etc.) are not directly interchangeable without software adaptation. Confirm no hardware self‑diagnosis fault alarm before commissioning.
Typical Application Scenarios Special signal‑processing mixed‑I/O module for UNITROL6000/6800 static excitation‑systems of medium‑large synchronous‑generators in thermal‑power plants, hydropower plants and industrial self‑power‑stations, used for excitation‑cabinet maintenance and spare‑part replacement.
Key Features
- Special signal‑processing I/O module for AC800PEC excitation platform, provides isolation and conditioning for CT/VT measuring loop, improves anti‑interference performance of sampling channels.
- Integrate multi‑channel analog and binary signal processing resources, act as signal interface between field hardware and excitation main‑controller.
- Rack plug‑in mechanical structure, convenient for on‑site replacement and maintenance.
- Built‑in channel self‑diagnosis function, easy for on‑site fault locating.
- Important maintenance spare‑part for ABB UNITROL excitation‑systems; strict attention to suffix‑version matching during spare‑part replacement.