Description
Hardware and Performance Specifications Auxiliary supply: 24 V DC, support 9‑36 V DC wide‑range input Power consumption: ≤15 W Analog channels: multi‑channel galvanic‑isolated analog input for generator voltage, stator current, rotor excitation current and cabinet temperature signals; optimized signal‑conditioning circuit, 16‑bit ADC sampling Binary I/O: multi‑group isolated digital input and output channels for cabinet switch‑status collection and interlock‑alarm signal transmission Communication interfaces: AC800PEC rack internal back‑plane bus Mounting mode: rack plug‑in module for excitation cabinet AC800PEC rack Operating temperature: ‑20 ℃ ~ +70 ℃ Storage temperature: ‑40 ℃ ~ +85 ℃ Humidity: 5‑95 %RH non‑condensing EMC compliance: IEC 61000‑4 series industrial electromagnetic compatibility standards Dimension & weight: approx. 210 × 145 × 50 mm, weight about 1.3 kg Certifications: CE approval
Main Functions Realize isolation filtering and signal conditioning for generator terminal voltage, stator current, rotor excitation‑current analog signals, suppress strong electromagnetic interference from power‑plant field environment. Complete A/D conversion for excitation‑system measuring analog quantities, transmit sampling data to excitation main‑controller through back‑plane bus. Collect cabinet‑site binary signals: breaker auxiliary contact, cooling‑fan status, cooling‑water flow, cabinet‑door interlock and other switch‑quantity signals. Receive control commands from main‑controller, convert and output binary interlock and alarm signals. Front‑panel LED indicators show channel operating status and fault codes. Hardware self‑diagnosis detects channel abnormal and internal circuit fault, upload fault information to main‑controller. Channel parameter configuration and debugging are finished by UNITROL Configurator and Control Builder M engineering software.
Installation Requirement Plug‑in installation inside AC800PEC rack of excitation cabinet. High‑power cables and weak‑signal sampling cables shall be routed separately, ensure reliable cabinet grounding. Auxiliary 24 V DC power supply must stay within rated working range. After module replacement, confirm hardware suffix version A1501 strictly matches original project configuration, download complete excitation project configuration file. Perform analog‑channel calibration, binary‑I/O point‑to‑point test and back‑plane bus communication inspection. This module must match excitation main‑controller and cannot run alone. Different suffix variants of UAD149 series (A0001/A0011/A1501) are not directly interchangeable without software adaptation and channel parameter modification. Confirm no hardware self‑diagnosis fault alarm before commissioning.
Typical Application Scenarios Special signal‑processing mixed‑I/O module for UNITROL6000/6800 static excitation‑systems of medium‑large synchronous‑generators in thermal‑power plants, hydropower plants and nuclear‑power‑plants, used for excitation‑cabinet maintenance and spare‑part replacement.
Key Features
- Special signal‑processing I/O module for AC800PEC excitation platform, A1501 version adopts optimized conditioning circuit for large‑unit excitation measuring loop.
- Provide galvanic isolation for CT/VT measuring loop, improve anti‑interference performance of sampling channels under complex field conditions.
- Integrate multi‑channel analog and binary signal processing resources, act as signal interface between field hardware and excitation main‑controller.
- Rack plug‑in mechanical structure, convenient for on‑site replacement and maintenance.
- Built‑in channel self‑diagnosis function, easy for on‑site fault locating.
- Important maintenance spare‑part for ABB UNITROL excitation‑systems; strict attention to suffix‑version matching during spare‑part replacement, cannot arbitrarily replace with A0001/A0011.




-300x300.jpg)