Description
Hardware & Electrical Specifications
- Model:UCD208A101
- Part Number:3BHE020018R0101
- Module Type:Sequence Control & Binary Logic Board
- Bus Interface:Internal high‑speed back‑plane connector for data exchange with main processor
- Binary Input:Multi‑channel isolated dry‑contact binary input channels
- Binary Output:Multi‑channel on‑board relay contact output channels
- Power supply:24 V DC cabinet internal power supply
- Max power consumption:13 W
- Galvanic isolation:≥2500 V AC between field‑signal side and control‑logic side
- Dielectric strength:2500 V AC 1 minute
- Insulation resistance:>100 MΩ @ 500 V DC
- On‑board protection:ESD protection, surge suppression for relay contacts, contact‑fault monitoring circuit, conformal coated PCB
- Compatibility note:Must match UNITROL6000 full‑system firmware; cannot operate standalone, must cooperate with PPC‑series main‑processor hardware.
Environmental Specifications
- Operating temperature:‑10 ℃ ~ +60 ℃
- Storage temperature:‑40 ℃ ~ +85 ℃
- Relative humidity:5%‑95% non‑condensing
- Protection degree:Installed inside excitation cabinet rack
- EMC compliance:IEC 61000‑6‑2 industrial electromagnetic immunity standard
- Certifications:CE
Mechanical Data
- Installation:Plug‑in rack‑mount board, inserted into designated slot of UNITROL6000 cabinet
- Interfaces:Internal back‑plane connector; external terminal blocks for binary‑input and relay‑output wiring
- Suitable wire cross‑section:0.75 mm²‑2.5 mm² copper cable for signal terminals
- Terminal tightening torque:0.6‑1.0 N·m
- Weight:approx 1.22 kg
- Dimension:Standard Euro‑card form‑factor for UNITROL6000 rack
Main Functions
- Excitation sequence logic processing: Receives logic commands from main processor, executes generator excitation start‑up, shutdown sequence and auxiliary‑equipment linkage logic.
- Relay‑type binary output driving: On‑board relay contact outputs for excitation breaker control, system alarm indication, external interlock signal output.
- Binary dry‑contact signal acquisition: Collects cabinet auxiliary contact status, converts field contact signals into digital logic for interlock‑protection condition judgment.
- Interlock‑condition monitoring: Monitors critical interlock‑signal status, triggers blocking logic when abnormal‑condition detected, reports interlock‑event codes to main processor.
- Relay‑channel fault diagnosis: Detects relay‑output abnormal, input‑signal loss and channel fault status, uploads detailed fault information to UNITROL6000 system.
- Board‑level comprehensive self‑diagnosis: Monitors on‑board power supply and hardware‑logic running status; reports hardware‑fault alarm to main processor.
- On‑board multi‑LED status indication
- Green LED:Board power supply normal, board logic running healthy
- Yellow LED:Binary‑input / output channel signal active
- Red LED:Interlock‑fault / relay‑channel fault / board hardware fault alarm
Installation & Wiring Requirements
- Cut off cabinet total power before disassembly and assembly. Insert UCD208A101 into designated rack slot and fasten fixing screws firmly. Hot‑swap is strictly forbidden.
- Connect field binary‑input cables and relay‑output control cables to corresponding terminal blocks; strictly follow excitation cabinet wiring specification; separate high‑power cables and weak‑signal cables to reduce electromagnetic interference.
- Cabinet protective grounding must comply with ABB AC800‑PEC / UNITROL6000 system grounding specification.
- After replacement, verify full‑system firmware compatibility with main processor board; download matching project parameters; perform binary‑input acquisition test and relay‑output function test before unit commissioning.
- Replacement note: Cannot run independently; must match corresponding main‑processor hardware and full‑system firmware version.