Description
Hardware & Electrical Specifications
- Model:XVC724BE102
- Part Number:3BHE009017R0102
- Module Type:VLSCD Voltage Level Short‑Circuit Detection Board
- Bus Interface:Internal drive system back‑plane signal interface
- Signal Interface:Voltage sampling input terminals, fault trigger signal output channels
- Power supply:24 V DC (18‑32 V DC)
- Max power consumption:10 W
- Galvanic isolation:≥2500 V AC between high‑voltage sampling side and control‑logic side
- Dielectric strength:2500 V AC 1 minute
- Insulation resistance:>100 MΩ @ 500 V DC
- On‑board protection:ESD protection, surge suppression for voltage sampling circuit, hardware fault latch circuit, conformal coated PCB
- Compatibility note:Cannot run standalone; dedicated for ACS2000 medium‑voltage converter, must match drive system firmware version.
Environmental Specifications
- Operating temperature:‑25 ℃ ~ +85 ℃
- Storage temperature:‑40 ℃ ~ +90 ℃
- Relative humidity:5%‑95% non‑condensing
- Installation location:Inside ACS2000 medium‑voltage drive cabinet
- EMC compliance:IEC 61000‑6‑2
- Certifications:CE
Mechanical Data
- Installation:Plug‑in rack‑mount eurocard board
- Interfaces:Internal back‑plane connector; external voltage sampling & fault‑signal terminal blocks
- Recommended wire cross‑section:0.75 mm²‑2.5 mm² copper cable for signal terminals
- Terminal tightening torque:0.6‑1.0 N·m
- Weight:approx 0.85 kg
- Dimension:Standard Euro‑card for ACS2000 drive rack
Main Functions
- Real‑time sampling and monitoring of medium‑voltage inverter output voltage.
- Fast detection of output short‑circuit and sudden voltage drop fault, hardware‑level rapid response.
- Output fault trigger signal to main control board, trigger drive trip sequence to protect power unit.
- Hardware fault latch function, keep fault status until manual reset.
- Board self‑diagnosis: detect sampling circuit abnormality and board power‑supply failure, report fault code to drive system.
- LED status indication:
- Green LED:Power supply normal, board logic healthy
- Yellow LED:Voltage sampling signal active
- Red LED:Short‑circuit fault / sampling channel fault / board hardware fault
Installation & Wiring Requirements
- Cut off cabinet total power before installation or replacement. Insert XVC724BE102 into assigned rack slot and tighten mounting screws. Hot‑swap is strictly forbidden.
- Connect high‑voltage sampling cables and fault‑signal cables strictly per wiring drawing; separate high‑power cables and weak‑signal cables to reduce electromagnetic interference.
- Cabinet protective grounding shall comply with ABB ACS2000 system grounding specification.
- After replacement, confirm firmware compatibility, perform voltage sampling calibration and short‑circuit protection simulation test before commissioning.
- Replacement note: Cross‑version substitution requires hardware‑firmware compatibility validation.