ABB XVC767AE102 3BHB007209R0102 Voltage & Current Monitoring Scaling Board

XVC767AE102 (3BHB007209R0102) is conformal‑coated plug‑in monitoring signal‑conditioning board for ABB IGCT‑based high‑power converter systems (ACS6000 / Megadrive‑LCI). It performs high‑precision scaling, filtering and isolation for DC‑link voltage, phase current and power‑unit temperature signals. It converts high‑power side raw sampling signals into standard low‑level signals and transmits them to main CPU board via internal back‑plane bus. It implements hardware pre‑detection for over‑voltage, under‑voltage, over‑current and over‑temperature faults. Product status: Obsolete, spare‑part only supply available。

Email:2735429704@qq.com
Phone:+86 19316626421

Description

Hardware & Electrical Specifications

  • Model:XVC767AE102
  • Part Number:3BHB007209R0102
  • Module Type:Voltage & Current Monitoring Scaling Board
  • Bus Interface:Internal converter system back‑plane signal bus
  • Signal Channel:DC‑link voltage sampling inputs, multi‑phase current sampling inputs, temperature sensor input channels
  • Power supply:24 V DC (18‑32 V DC)
  • Max power consumption:11 W
  • Galvanic isolation:≥2500 V AC between high‑power sampling side and control‑logic side
  • Dielectric strength:2500 V AC 1 minute
  • Insulation resistance:>100 MΩ @ 500 V DC
  • On‑board protection:ESD protection, multi‑stage signal surge suppression, analog filter circuit, hardware fault latch, conformal coated PCB
  • Compatibility note:Cannot run standalone; dedicated for ACS6000 / Megadrive‑LCI converter rack, must match corresponding system firmware version.

Environmental Specifications

  • Operating temperature:‑10 ℃ ~ +60 ℃
  • Storage temperature:‑40 ℃ ~ +85 ℃
  • Relative humidity:5%‑95% non‑condensing
  • Installation location:Inside high‑power converter cabinet rack
  • EMC compliance:IEC 61000‑6‑2
  • Certifications:CE

Mechanical Data

  • Installation:Plug‑in rack‑mount eurocard board
  • Interfaces:Internal back‑plane connector; external sampling signal terminal blocks
  • Recommended wire cross‑section:0.75 mm²‑2.5 mm² copper cable for signal terminals
  • Terminal tightening torque:0.6‑1.0 N·m
  • Weight:approx 0.82 kg
  • Dimension:Standard Euro‑card for ABB high‑power converter rack

Main Functions

  1. High‑precision signal scaling and conditioning for DC‑link voltage, phase current and power‑device temperature signals.
  2. Galvanic isolation between high‑voltage power section and low‑voltage control rack, suppress strong electromagnetic interference.
  3. Hardware pre‑monitoring: detect over‑voltage, under‑voltage, over‑current and over‑temperature, output fast fault trigger signal.
  4. Send processed measuring data to main processor via back‑plane bus for closed‑loop control and fault recording.
  5. Board‑level self‑diagnosis: detect sampling‑circuit abnormality and board power‑supply failure, report fault codes to converter system.
  6. LED status indication:
    • Green LED:Power supply normal, board logic healthy
    • Yellow LED:Sampling signal active
    • Red LED:Sampling channel fault / power‑unit protection fault / board hardware fault

Installation & Wiring Requirements

  1. Cut off cabinet total power before installation or replacement. Insert XVC767AE102 into assigned rack slot and tighten mounting screws. Hot‑swap is strictly forbidden.
  2. Connect voltage/current sampling cables and temperature‑sensor cables strictly per wiring drawing; separate high‑power cables and weak‑signal cables to reduce electromagnetic interference.
  3. Cabinet protective grounding shall comply with ABB ACS6000 / Megadrive‑LCI grounding specification.
  4. After replacement, confirm firmware compatibility, complete signal calibration and protection‑function simulation test before commissioning.
  5. Replacement note: Cross‑version substitution requires hardware‑firmware compatibility validation

Reviews

There are no reviews yet.

Be the first to review “ABB XVC767AE102 3BHB007209R0102 Voltage & Current Monitoring Scaling Board”

Your email address will not be published. Required fields are marked *