Description
Hardware & Electrical Specifications
- Model:XVC768BE102(Alias:XVC768102)
- Part Number:3BHB007211R102
- Module Type:Current Measurement Monitoring Board
- Bus Interface:Internal converter system back‑plane signal bus
- Signal Channel:Multi‑phase current sampling input channels, analog measuring output channels
- Power supply:24 V DC (18‑32 V DC)
- Max power consumption:11 W
- Galvanic isolation:≥2500 V AC between power‑unit sampling side and control‑logic side
- Dielectric strength:2500 V AC 1 minute
- Insulation resistance:>100 MΩ @ 500 V DC
- On‑board protection:ESD protection, multi‑stage surge suppression for current sampling circuit, analog filter circuit, hardware fault latch, conformal coated PCB
- Compatibility note:Cannot run standalone; dedicated for ACS6000 / Megadrive‑LCI converter rack, must match corresponding system firmware version.
Environmental Specifications
- Operating temperature:‑10 ℃ ~ +60 ℃
- Storage temperature:‑40 ℃ ~ +85 ℃
- Relative humidity:5%‑95% non‑condensing
- Installation location:Inside high‑power converter cabinet rack
- EMC compliance:IEC 61000‑6‑2
- Certifications:CE
Mechanical Data
- Installation:Plug‑in rack‑mount eurocard board
- Interfaces:Internal back‑plane connector; external current‑sampling signal terminal blocks
- Recommended wire cross‑section:0.75 mm²‑2.5 mm² copper cable for signal terminals
- Terminal tightening torque:0.6‑1.0 N·m
- Weight:approx 0.80 kg
- Dimension:Standard Euro‑card for ABB high‑power converter rack
Main Functions
- High‑precision acquisition, filtering and scaling conditioning for converter phase current signals.
- Galvanic isolation between high‑power power section and low‑voltage control rack, suppress heavy electromagnetic interference.
- Hardware‑level pre‑detection of over‑current fault, output fast fault trigger signal for protection trip.
- Send processed current measuring data to main processor for closed‑loop current‑torque control and fault event recording.
- Channel‑level self‑diagnosis: detect sampling‑circuit abnormality and board power‑supply failure, report fault codes to converter system.
- LED status indication:
- Green LED:Power supply normal, board logic healthy
- Yellow LED:Current sampling signal active
- Red LED:Sampling channel fault / over‑current pre‑alarm / board hardware fault
Installation & Wiring Requirements
- Cut off cabinet total power before replacement. Insert XVC768BE102 into assigned rack slot and tighten mounting screws. Hot‑swap is strictly forbidden.
- Connect current‑sampling cables strictly per wiring drawing; strictly separate high‑power cables and weak‑signal cables to reduce electromagnetic interference.
- Cabinet protective grounding shall comply with ABB ACS6000 / Megadrive‑LCI grounding specification.
- After replacement, confirm firmware compatibility, complete current‑sampling calibration and over‑current protection simulation test before commissioning.
- Replacement note:Cross‑version substitution requires hardware‑firmware compatibility validation.