ABB XVC770BE101 3BHE021083R0101 DC‑Link High‑Voltage Detection Board

XVC770BE101 (3BHE021083R0101) is conformal‑coated plug‑in HVD high‑voltage detection board, hardware upgraded variant of XVC770AE, for ABB ACS6000 / Megadrive‑LCI high‑power converter systems. It samples DC‑link high‑voltage signals, implements isolation conversion, hardware fast over‑voltage / under‑voltage fault detection. It transmits scaled measuring values to main control unit via internal back‑plane bus, outputs hardware trip trigger signal to protect IGCT power semiconductors when voltage exceeds threshold. Product status: Obsolete, spare‑part only supply available。

Email:2306444920@qq.com
Phone:+86 17759635229

Description

Hardware & Electrical Specifications

  • Model:XVC770BE101
  • Part Number:3BHE021083R0101
  • Module Type:DC‑Link High‑Voltage Detection HVD Board
  • Bus Interface:Internal converter system back‑plane signal bus
  • Signal Channel:DC‑link high‑voltage sampling input, analog measuring output, hardware fault trigger output
  • Power supply:24 V DC (18‑32 V DC)
  • Max power consumption:10 W
  • Galvanic isolation:≥3000 V AC between high‑voltage sampling side and control‑logic side
  • Dielectric strength:3000 V AC 1 minute
  • Insulation resistance:>100 MΩ @ 500 V DC
  • On‑board protection:ESD protection, high‑voltage surge suppression, hardware voltage comparator latch circuit, conformal coated PCB
  • Compatibility note:Cannot run standalone; dedicated for ACS6000 / Megadrive‑LCI converter rack, must match corresponding system firmware version. Direct swap with XVC770AE needs hardware‑firmware compatibility validation.

Environmental Specifications

  • Operating temperature:‑10 ℃ ~ +60 ℃
  • Storage temperature:‑40 ℃ ~ +85 ℃
  • Relative humidity:5%‑95% non‑condensing
  • Installation location:Inside high‑power converter cabinet rack
  • EMC compliance:IEC 61000‑6‑2
  • Certifications:CE

Mechanical Data

  • Installation:Plug‑in rack‑mount eurocard board
  • Interfaces:Internal back‑plane connector; high‑voltage sampling terminals; fault‑signal output terminal blocks
  • Recommended wire cross‑section:0.75 mm²‑2.5 mm² copper cable for signal terminals
  • Terminal tightening torque:0.6‑1.0 N·m
  • Weight:approx 0.78 kg
  • Dimension:Standard Euro‑card for ABB high‑power converter rack

Main Functions

  1. Real‑time sampling and galvanic isolation conversion of converter DC‑link high‑voltage signal.
  2. Hardware‑level fast over‑voltage / under‑voltage detection, independent of main‑processor software logic.
  3. Output hardware fault trigger signal to control system to execute trip sequence once voltage threshold exceeded.
  4. Send scaled analog measuring data to main processor for closed‑loop control and high‑voltage monitoring.
  5. Board‑level self‑diagnosis: detect sampling‑circuit abnormality and board power‑supply failure, report fault codes to converter system.
  6. LED status indication:
    • Green LED:Power supply normal, board logic healthy
    • Yellow LED:High‑voltage sampling signal active
    • Red LED:Over‑voltage / under‑voltage fault / sampling channel fault / board hardware fault

Installation & Wiring Requirements

  1. Cut off cabinet total power before replacement. Insert XVC770BE101 into assigned rack slot and tighten mounting screws. Hot‑swap is strictly forbidden.
  2. Connect DC‑link sampling cables and fault‑signal cables strictly per wiring drawing; strictly separate high‑voltage sampling cables and low‑voltage signal cables to reduce electromagnetic interference.
  3. Cabinet protective grounding shall comply with ABB ACS6000 / Megadrive‑LCI grounding specification.
  4. After replacement, confirm firmware compatibility, complete high‑voltage sampling calibration and over‑voltage protection simulation test before commissioning.
  5. Replacement note:Cross‑version substitution requires hardware‑firmware compatibility confirmation.

Reviews

There are no reviews yet.

Be the first to review “ABB XVC770BE101 3BHE021083R0101 DC‑Link High‑Voltage Detection Board”

Your email address will not be published. Required fields are marked *