Description
Hardware & Electrical Specifications
‑ Manufacturer: Bently Nevada (Baker Hughes) ‑ Device Type: 3500/25 Keyphasor Rear I/O Module, internal termination ‑ Number of Keyphasor Input Channels: 2 independent input channels ‑ Supported Sensor Types: Magnetic pickup sensors, proximity‑type keyphasor probes ‑ Proximity Probe Excitation: ‑24 Vdc power supply for eddy‑current keyphasor probes ‑ Input Impedance: Minimum 21.8 kΩ per channel ‑ Input Frequency Range: 0‑10 kHz (‑3 dB) ‑ Termination: Multi‑position screw‑type terminal blocks for field‑signal wiring ‑ Backplane Interface: 3500 proprietary backplane connector mating with front‑side 3500/25 main module ‑ Typical Power Consumption: 3.2 W ‑ Mounting: Full‑height rear slot installation inside 3500‑series rack chassis ‑ PCB Treatment: Conformal‑coated printed‑circuit board ‑ Operating Temperature: ‑30 ℃ ~ +65 ℃ ‑ Storage Temperature: ‑40 ℃ ~ +85 ℃ ‑ Certifications: CE, CSA, ATEX hazardous‑area approvals, API‑670 compliant
Environmental Specifications
‑ Relative Humidity: 5%‑95 %, non‑condensing ‑ Vibration Resistance: Complies with industrial cabinet mechanical vibration requirements ‑ EMI Immunity: On‑board signal filtering suppresses interference induced by power cables and variable‑frequency‑drive equipment
Core Functions
- Keyphasor‑sensor signal termination: Provides screw terminals for two‑channel keyphasor field wiring, accepts pulse signals from magnetic pickups or proximity keyphasor probes.
- Transducer power supply: Delivers regulated ‑24 Vdc excitation power for proximity‑type keyphasor probe assemblies.
- Pulse‑signal conditioning: Processes raw shaft‑mark pulse signals and sends conditioned keyphasor events to front‑side 3500/25 module through rack backplane bus.
- Speed‑and‑phase reference distribution: Cooperates with front‑panel 3500/25 module to generate shaft rotating‑speed and phase‑reference data, shared across the 3500 rack for vibration vector calculation of radial‑vibration monitor channels.
- Transducer loop diagnostics: Detects open‑circuit and short‑circuit faults on each keyphasor channel and reports loop‑fault status to the front‑side main module for system alarming.
Installation, Replacement & Critical Warnings
- This rear I/O module supports hot‑swap operation. Rack main power may remain energized for module replacement, but field sensor wiring shall be de‑energized before modifying terminal connections.
- Compatibility warning: ‑ Strictly matched with front‑side 3500/25 Enhanced Keyphasor main module; cannot work with other monitor modules. ‑ Select correct sensor type (magnetic pickup or proximity probe) in rack configuration software according to actual field hardware. ‑ Keyphasor signal cables shall be routed separately from high‑voltage power cables to avoid pulse‑signal distortion by electromagnetic noise. ‑ Tighten terminal screws to proper torque to prevent poor contact; avoid stray wire strands inside terminal block. ‑ Inspect backplane connector pins for bending, debris and corrosion before inserting module into rear slot.
- Post‑replacement commissioning and verification: ‑ Confirm module is fully seated in rear slot with reliable backplane connection. ‑ Check front‑panel status LED of paired 3500/25 module; no hardware‑fault or loop‑fault indication under normal condition. ‑ Apply simulated pulse signal to each channel, verify shaft‑speed reading responds correctly to pulse frequency change. ‑ Simulate sensor open‑circuit and short‑circuit conditions, confirm channel loop‑fault alarm triggers properly. ‑ Under machine running conditions, verify stable speed value and valid phase‑angle readings on related vibration monitor channels.






Reviews