Bently 16413-1-3 Keyphasor Signal Interconnect Cable

16413‑1‑3 is a dedicated shielded Keyphasor interconnection cable assembly for Bently Nevada 3500 monitoring system. It is used to transmit Keyphasor phase‑reference pulse signal from probe / proximitor output to monitor‑module channel. Length: 3 meter. It adopts triple‑axial shielded cable construction, suppresses external EMI interference, ensures clean phase‑trigger pulse for rotating‑machinery speed, phase and orbit analysis.

Email:2735429704@qq.com
Phone:+86 19316626421

Description

Hardware & Electrical Specifications

‑ Manufacturer: Bently Nevada (Baker Hughes) ‑ Functional Type: Keyphasor Phase‑Reference Signal Interconnect Cable Assembly ‑ Cable Length: 3 m ‑ Cable Structure: Tri‑axial shielded, EMI‑suppressed ‑ Characteristic Impedance: 75 Ω ‑ Connector Type: Miniature coaxial connectors at both ends ‑ Operating Temperature:‑51 ℃ ~ +177 ℃ ‑ Storage Temperature:‑55 ℃ ~ +185 ℃ ‑ Minimum Bend Radius: 25.4 mm (1 inch), do not over‑bend ‑ Weight: approx 0.21 kg ‑ Armor: Non‑armored standard version ‑ Agency Certification: CE, CSA hazardous‑area approvals available

Environmental Specifications

‑ Operating Temperature:‑51 ℃ ~ +177 ℃ ‑ Storage Temperature:‑55 ℃ ~ +185 ℃ ‑ Relative Humidity:5%‑95 % non‑condensing ‑ Vibration: Complies with API‑670 field‑wiring requirements

Core Functions

  1. Keyphasor pulse signal transmission: Deliver clean phase‑reference trigger pulse from proximitor output to 3500/25 monitor module, for shaft speed, phase angle, orbit and order‑analysis calculation.
  2. EMI noise suppression: Multi‑layer shielding reduces industrial‑site electromagnetic interference, avoids pulse distortion and missing trigger events.
  3. System signal matching: Fixed electrical‑length assembly maintains impedance matching for correct Keyphasor signal waveform.

Installation, Replacement & Critical Warnings

  1. Non‑hot‑swap field‑wiring component; de‑energize relevant channel during replacement.
  2. Compatibility warning: ‑ Pre‑fabricated 3‑meter assembly; do not cut, splice or re‑terminate on‑site. ‑ Mainly used with 3500/25 Keyphasor‑speed monitor module and compatible proximitor. ‑ Inspect connector pins for bending, corrosion and contamination during installation.
  3. After replacement: Verify speed reading, key‑phasor trigger status in rack configuration software; confirm orbit‑diagram function is normal.
  4. Common failure mode: Internal conductor breakage, connector pin damage, shielding degradation; symptoms: intermittent / lost speed signal, missing key‑phasor event, orbit‑plot unavailable. Cable fault itself will not initiate machinery‑protection trip.

Reviews