Description
Hardware Specifications
- Part Type: 3300‑XL proximitor sensor (pre‑amplifier), gold‑plated ClickLoc input connector, SpringLoc tool‑free output terminals
- Calibrated Total System Length: 5.0 meters (16.4 ft)
- Sensitivity: 7.87 V/mm (200 mV/mil), tolerance ±5 %; linear measuring range 2.0 mm (80 mil)
- Power Supply: −17.5 Vdc ~ −26 Vdc, maximum operating current 12 mA
- Mechanical Construction: Die‑cast aluminum housing; dual mounting options: standard 4‑hole panel mount or DIN‑rail mount; electrically‑isolated mounting base, no separate insulating plate required; unit weight 246 g
- Environmental Ratings: Operating temperature ‑35 °C ~ +85 °C; storage ‑52 °C ~ +100 °C; relative humidity 5‑95 % non‑condensing
- Electrical Compatibility: Works with 3300‑XL 5 mm / 8 mm proximity probes and matching 3300‑XL extension cables. The sum of probe integral cable plus extension cable must exactly match 5.0 m calibrated system length. Suffix‑00 denotes standard version without international hazardous‑location approvals。
Core Functions
- Excites eddy‑current proximity probe, receives high‑frequency sensor signal and converts probe‑to‑shaft gap distance into stable DC gap‑voltage output for radial‑vibration, thrust‑position and shaft‑position measurement.
- Deployed on steam‑turbines, gas‑turbines, centrifugal compressors and other critical rotating‑machinery as core component of 3300‑XL transducer set; output signal feeds to 3500‑series / 1900‑series monitoring systems for machinery protection and condition‑diagnosis.
- High RFI/EMI immunity; can be installed inside fiberglass enclosures without extra metallic shielding, meets CE electromagnetic compatibility requirements。
- SpringLoc spring‑clamp terminals enable fast, tool‑less field wiring for output power and signal connections.
- Widely used in power‑generation, petrochemical and oil‑gas industrial sites. Distinguished ordering code:‑50‑ defines 5 m calibrated total system length,‑00‑ defines standard non‑agency variant. Replacement requires strict matching of total transducer‑system length and gap‑voltage calibration verification。
Installation Requirements
- Mounting requirement: Support either 4‑hole panel mounting or DIN‑rail mounting. Mounting base provides electrical isolation; do not bypass internal isolation. Avoid mounting location with direct high‑temperature radiation or heavy‑fluid splashing onto housing.
- Transducer connection: Mate ClickLoc probe‑side connector finger‑tight plus maximum 1/8‑turn; over‑torque will damage gold‑plated contact pins. Do not disassemble ClickLoc connector assembly.
- Terminal wiring: Insert stripped wire into SpringLoc terminals and close spring clamp; ensure no loose wire strands. Follow polarity for negative supply power, signal output and common return.
- Grounding rule: Transducer shield single‑point grounding strictly at proximitor‑sensor common terminal only; multi‑point shield grounding will induce ground‑loop noise.
- Environmental control: Housing is not submersible; protect unit against oil, water and process‑fluid spray. Ambient operating temperature must stay within‑35 °C ~ +85 °C range.
- Pre‑installation visual inspection: Inspect aluminum housing for deformation; inspect ClickLoc input connector pins for bending, corrosion or contamination; inspect SpringLoc terminals for damage before commissioning. After full transducer assembly, measure static gap‑voltage to confirm valid linear‑range operation.
- Part‑number cross‑version distinction: 330180‑50‑00 is 5 m calibrated proximitor without hazardous‑area certifications. Different‑system‑length proximitors are not drop‑in substitutes. Hazardous‑approved or CN‑regional variants cannot be swapped without re‑calculating full transducer‑system length and performing gap‑voltage calibration.
Common Failure Modes
‑ ClickLoc connector pin contamination, corrosion or over‑torque damage: unstable signal connection, high‑frequency noise superimposed on gap‑voltage output. ‑ Mismatched total transducer‑system cable length: incorrect sensitivity, gap‑voltage offset, invalid measurement data. ‑ Improper power supply voltage or reversed polarity: no output signal, permanent internal proximitor damage. ‑ Multi‑point shield grounding: ground‑loop induced noise, unstable gap‑voltage drift. ‑ SpringLoc terminal poor wire clamping: intermittent signal loss or fluctuating readings under vibration. ‑ Excessive ambient temperature beyond specification: gradual sensitivity drift, premature unit failure.





Reviews
There are no reviews yet.