Description
Hardware & Electrical Specifications
‑ Manufacturer: Bently Nevada (Baker Hughes) ‑ Compatible System: Bently Nevada 3500 TSI machinery protection rack ‑ Functional Type: Universal AC Power Supply Main Conversion Module ‑ Mandatory mating part: 106M1081‑01(PIM AC power input small card) ‑ Input Source: Processed AC power from 106M1081‑01 ‑ AC Input Range(whole set):85‑264 VAC, 47‑63 Hz ‑ Max Output Power:120 W, capable of powering full‑size 14‑slot 3500 rack ‑ DC Output Rails: ±5 VDC, ±15 VDC, 24 VDC backplane power bus ‑ Protection Circuit: Over‑voltage, over‑current, over‑temperature, short‑circuit fold‑back protection ‑ Front‑panel Indicator: SUPPLY OK green LED for power‑supply health diagnosis ‑ Connectors: Internal edge‑connector mates with 106M1081‑01; backplane edge connector for rack power bus ‑ Mounting: Half‑height slot on left dedicated position of 3500‑05 rack ‑ PCB Coating: Conformal coated for G3 harsh industrial cabinet environment ‑ Hot‑swap condition: Hot‑swap allowed only when second redundant power supply is online. Must cut off upstream AC input under single‑power configuration before replacement
Environmental Specifications
‑ Operating Temperature: ‑40 °C ~ +70 °C, power derating above 60 °C ‑ Storage Temperature: ‑40 °C ~ +85 °C ‑ Relative Humidity:5%‑95 % non‑condensing ‑ Vibration & Shock: Complies with API‑670 power‑plant cabinet EMC standards
Mechanical Data
‑ Dimension(W×H×D):50.8 mm ×120.7 mm ×251.5 mm ‑ Weight: approx 1.39 kg
Core Functions
- AC‑DC power conversion: Accept filtered AC power from PIM 106M1081‑01, convert to multi‑group stable DC power for entire 3500 rack backplane bus.
- Redundancy support: Dual‑set 106M1079‑01+106M1081‑01 assemblies can be configured for N+1 redundant power, improving system reliability for critical turbine/compressor protection.
- Multi‑layer fault protection: Built‑in OVP, OCP, OTP protection, isolates internal faults, avoids damaging other monitor modules on rack.
- Visual health diagnosis: Front‑panel SUPPLY‑OK LED gives quick status indication for field maintenance personnel.
- Full‑rack power driving: Provides stable working power for vibration, position, speed, relay and communication modules inserted in 3500 rack.
Installation, Replacement & Critical Warnings
- Under single‑power rack condition, fully de‑energize upstream 85‑264 VAC power before replacing either 106M1079‑01 or 106M1081‑01. Hot‑swap operation is permitted only when redundant backup power is running normally.
- Strict matching requirement: 106M1079‑01 must work with 106M1081‑01, cannot pair with legacy HV‑AC / LV‑AC PIM cards. Mismatched combination results in no output and hardware damage riskBaker Hugh….
- Check SUPPLY‑OK LED after installation; LED off indicates power‑subsystem fault. Check AC input, PIM and main card sequentially.
- After replacement, verify all rack modules boot normally, download system configuration software project.
-
Common failure mode: Surge damage on internal conversion circuit, component aging. Investigate site AC power quality when whole rack loses power.







Reviews
There are no reviews yet.