Description
Hardware & Electrical Specifications
‑ Manufacturer: Bently Nevada (Baker Hughes) ‑ Compatible System: Bently Nevada 3500 machinery‑protection TSI rack ‑ Functional Type: Legacy Low‑Voltage AC Power Supply Big‑Card ‑ AC Input: 85‑132 VAC, 47‑63 Hz ‑ Max Output Power:100 W, support full‑load 14‑slot full‑size rack ‑ DC Backplane Output: ±5 VDC, ±15 VDC, 24 VDC ‑ Protection Circuit: Over‑voltage, over‑current, over‑temperature, short‑circuit fold‑back protection ‑ Front‑panel Indicator: SUPPLY OK green LED for power‑supply health diagnosis ‑ Connectors: AC input screw terminals on front panel; edge‑connector connects to rack backplane ‑ Mounting: Half‑height dedicated slot on left side of 3500‑05 rack ‑ PCB Coating: Conformal coated for G3 harsh industrial cabinet environment ‑ Hot‑swap rule: Hot‑swap permitted only when second redundant power supply works normally. Must cut off upstream AC input under single‑power configuration before replacement
Environmental Specifications
‑ Operating Temperature: ‑40 °C ~ +70 °C, power derating above 60 °C ‑ Storage Temperature: ‑40 °C ~ +85 °C ‑ Relative Humidity:5%‑95 % non‑condensing ‑ Vibration & Shock: Complies with API‑670 power‑plant cabinet EMC standards
Mechanical Data
‑ Dimension(W×H×D):50.8 mm ×120.7 mm ×251.5 mm ‑ Weight: approx 1.14 kg
Core Functions
- LV‑AC to multi‑rail DC conversion: Single‑board completes AC input filtering, surge suppression and AC‑DC conversion, provides stable DC power for 3500 rack backplane bus.
- Redundancy support: Two 127610‑01 can be configured as 1+1 redundant power; lower‑slot module is primary, upper‑slot module is backup, seamless switch‑over occurs upon primary failure without rack shutdown.
- Multi‑layer fault protection: Built‑in OVP, OCP, OTP protection mechanism, isolate internal faults to avoid damaging other monitoring modules.
- Visual health diagnosis: Front‑panel SUPPLY‑OK LED indicates working status for field maintenance personnel.
- Full‑rack power driving: Supplies power for vibration, displacement, speed, relay and communication modules inserted in 3500 rack.
Installation, Replacement & Critical Warnings
- Under single‑power rack condition, fully de‑energize upstream AC power before replacing 127610‑01. Hot‑swap operation is only allowed when redundant backup power is online.
- Critical risk: This is low‑voltage AC power module, input only 85‑132 VAC. Direct connection to 220V mains will burn out the power card immediately. Cannot replace with 114M5330‑01 or split‑type 106M1079‑01+106M1081‑01 without modifying site power wiring. Confirm part number and input voltage before purchasing.
- After installation, check SUPPLY‑OK LED status; LED off indicates power‑subsystem fault. Check AC input loop and module sequentially.
- After replacement, verify all rack modules boot normally, download system configuration project via 3500 Rack Configuration software.
-
Common failure mode: Input circuit surge damage, internal power‑conversion component aging. Check site AC power quality when whole‑rack power‑loss occurs.







-300x300.jpg)