Bently 3500-64M 140734-05 Dynamic Pressure Monitor Main Board

140734‑05 is 4‑channel dynamic‑pressure monitor module for 3500 TSI machinery‑protection rack, compliant with API‑670 standard. It receives signals from high‑temperature dynamic pressure transducers, mainly used for gas‑turbine combustor combustion‑oscillation / combustion‑humming monitoring, detecting combustion instability, pressure pulsation and surge‑related pressure fluctuation.

Email:2735429704@qq.com
Phone:+86 19316626421

Description

Hardware & Electrical Specifications

‑ Manufacturer: Bently Nevada (Baker Hughes) ‑ Compatible System: 3500‑05 full‑size / mini TSI rack, cooperates with 3500/22M TDI module ‑ Functional Type: 4‑Channel Dynamic Pressure / Combustion Pulsation Monitor Module ‑ Channel quantity: 4 independent dynamic pressure input channels ‑ Supported transducers: 2‑wire / 3‑wire high‑temperature dynamic pressure sensors ‑ Input impedance: 3‑wire:10 kΩ; 2‑wire:1.5‑3.5 MΩ typical ‑ Nominal sensitivity:100 mV/psi (1.45 mV/mBar) ‑ Filter modes:  ‑ Low mode: 5 Hz ~ 4 kHz band‑pass  ‑ High mode:10 Hz ~14.75 kHz band‑pass  ‑ Notch filter:50 Hz / 60 Hz optional ‑ Measurement update rate: ≤100 ms ‑ Typical power consumption:8.2 W, powered by rack backplane bus ‑ Front‑panel Indicators: OK LED, TX/RX LED, Bypass LED; four short‑circuit‑protected BNC buffered signal outputs ‑ Matching Parts: Main‑board 140734‑05 must pair with rear I/O:140471‑02(Internal Termination) or 140482‑02(External Termination), sold separatelyBaker Hugh… ‑ Hot‑swap: Supports hot‑swap; during replacement, four‑channel dynamic‑pressure measurement is temporarily invalid; other rack modules keep running normally. ‑ PCB Coating: Conformal coated for G3 harsh industrial cabinet environment ‑ Safety Certification: SIL‑2 capable within complete certified 3500 TMR system set; ATEX, IECEx, cNRTLus hazardous‑area approvals available

Environmental Specifications

‑ Operating Temperature:0 ℃ ~ +65 ℃ ‑ Storage Temperature:‑40 ℃ ~ +85 ℃ ‑ Relative Humidity:5%‑95 % non‑condensing ‑ Vibration & Shock: Complies with API‑670 power‑plant cabinet EMC standards

Mechanical Data

‑ Dimension(W×H×D):241.3 mm ×24.4 mm ×241.8 mm ‑ Weight: approx 0.82 kg

Core Functions

  1. Dynamic‑pressure signal conditioning: Process 2‑wire / 3‑wire high‑temperature pressure‑transducer signals for combustion‑pulsation acquisition.
  2. Dual‑mode band‑pass filtering: Low‑frequency and high‑frequency filter groups for different combustion‑oscillation frequency bands; built‑in power‑frequency notch filter suppresses site interference.
  3. Cascade input function: One physical sensor input can be assigned to four channels with different filter parameters, multi‑frequency‑band simultaneous analysis.
  4. Flexible alarm configuration: Alert and Danger dynamic‑pressure setpoints with configurable delay; generate rack‑system events, trigger relay‑module alarm output.
  5. TMR redundant support: Can form triple‑modular‑redundant system with three identical modules for high‑safety machinery‑protection application.
  6. Self‑diagnosis: Continuous transducer cable fault detection; report module hardware fault to rack‑system log.

Installation, Replacement & Critical Warnings

  1. Supports hot‑swap; four‑channel dynamic‑pressure measurement loses effectiveness during pulling‑out; other rack modules keep running.
  2. Compatibility warning: ‑ Two rear‑I/O options: internal‑termination (direct wiring to rear‑card) or external‑termination (via external terminal block and dedicated connecting cable). Select I/O type according to site‑wiring scheme. ‑ Cannot swap main‑board or rear‑I/O between 3500/64M and old‑generation 3500/64. ‑ For TMR triple‑redundant configuration, three identical 140734‑05 modules must be installed in adjacent slots of rack.
  3. After replacement, check OK / Bypass LED status; download rack‑configuration project, complete dynamic‑pressure signal simulation test, verify channel reading and alarm‑trigger function.
  4. Common failure mode: Front‑end high‑frequency signal‑conditioning‑circuit damage, BNC‑connector wear, component aging; sensor‑cable short‑circuit / open‑circuit may affect channel measurement.

Reviews

There are no reviews yet.

Be the first to review “Bently 3500-64M 140734-05 Dynamic Pressure Monitor Main Board”

Your email address will not be published. Required fields are marked *