Bently 3500-77M 176449-07 Recip Cylinder Pressure Monitor Main Board

176449‑07 is a 4‑channel dedicated monitor module for 3500 TSI machinery‑protection rack, designed for reciprocating‑compressor cylinder pressure monitoring, API‑618 & API‑670 compliantBaker Hugh…. It receives voltage‑output signals from approved cylinder pressure transducers, calculates multiple cylinder‑cycle performance parameters, used for reciprocating‑compressor valve fault, ring leakage, rod‑load and rod‑reversal condition monitoring. Distinguished from vibration‑oriented 3500/70M: 3500/70M processes accelerometer vibration signals; 3500/77M processes cylinder dynamic‑pressure transducer signalsBaker Hugh…

Email:2735429704@qq.com
Phone:+86 19316626421

Description

Hardware & Electrical Specifications

‑ Manufacturer: Bently Nevada (Baker Hughes) ‑ Compatible System: 3500‑05 full‑size / mini TSI rack, cooperates with 3500/22M TDI module ‑ Functional Type:4‑Channel Reciprocating‑Compressor Cylinder‑Pressure Performance‑Monitor Module ‑ Channel quantity:4 independent pressure‑transducer input channels ‑ Supported transducers: Bently‑approved positive‑voltage output cylinder pressure transducers ‑ Transducer scale‑factor range:3800‑95000 mV/psi ‑ Input impedance: >1 MΩ ‑ Max pressure range:0‑3500 PSI ‑ Measurement accuracy: ±0.1 % full‑scale typical ‑ Typical power consumption:8.0 W, powered by rack backplane bus ‑ Front‑panel Indicators: OK LED, TX/RX LED, Bypass LED; four BNC buffered raw‑pressure‑signal outputs for field debugging ‑ Matching Parts: Main‑board 176449‑07 must pair with rear I/O:143729‑01(Internal Termination) or 143737‑01(External Termination), sold separately ‑ Hot‑swap: Supports hot‑swap; during replacement, four‑channel cylinder‑pressure measurement is temporarily invalid; other rack modules keep running normally. ‑ PCB Coating: Conformal coated for G3 harsh industrial cabinet environment ‑ Safety Certification: SIL‑2 capable within complete certified 3500 TMR system set; ATEX, CE hazardous‑area approvals available

Environmental Specifications

‑ Operating Temperature:0 ℃ ~ +65 ℃ ‑ Storage Temperature:‑40 ℃ ~ +85 ℃ ‑ Relative Humidity:5%‑95 % non‑condensing ‑ Vibration & Shock: Complies with API‑670 power‑plant cabinet EMC standards

Mechanical Data

‑ Dimension(W×H×D):241.3 mm ×24.4 mm ×241.8 mm ‑ Weight: approx 0.86 kg

Core Functions

  1. Cylinder‑pressure signal conditioning: Process voltage‑output pressure‑transducer signals for reciprocating‑compressor in‑cylinder pressure‑cycle acquisition.
  2. Thermodynamic‑parameter calculation: Suction / discharge pressure, peak / minimum pressure, compression ratio, rod tension‑compression load, rod‑reversal angle calculation, judge valve failure, piston‑ring leakage and abnormal rod‑load conditionsBaker Hugh….
  3. Flexible alarm configuration: Alert and Danger setpoints with configurable delay; generate rack‑system events, trigger relay‑module alarm output.
  4. TMR redundant support: Can form triple‑modular‑redundant system with three identical modules installed in adjacent slots for high‑safety reciprocating‑compressor protection application.
  5. Self‑diagnosis: Detect pressure‑transducer cable open‑circuit / short‑circuit fault; report module hardware fault to rack‑system log.

Installation, Replacement & Critical Warnings

  1. Supports hot‑swap; four‑channel cylinder‑pressure measurement loses effectiveness during pulling‑out; other rack modules keep running.
  2. Compatibility warning: ‑ Two rear‑I/O options: internal‑termination (wiring direct to rear‑card) or external‑termination (match external terminal‑block assembly). Select I/O type according to site‑wiring scheme. ‑ Cannot swap main‑board or rear‑I/O between 3500/77M and 3500/70M reciprocating‑vibration monitor module. ‑ For TMR triple‑redundant configuration, three identical 176449‑07 modules must be installed in adjacent slots of rack. ‑ Firmware requirement: module firmware revision L or higher is required for normal operation.
  3. After replacement, check OK / Bypass LED status; download rack‑configuration project, complete pressure‑signal simulation test, verify channel reading and alarm‑trigger function.
  4. Common failure mode: Front‑end high‑impedance signal‑conditioning‑circuit damage, BNC‑connector wear, component aging; pressure‑transducer‑cable short‑circuit / open‑circuit may affect channel measurement.

Reviews

There are no reviews yet.

Be the first to review “Bently 3500-77M 176449-07 Recip Cylinder Pressure Monitor Main Board”

Your email address will not be published. Required fields are marked *