Description
Hardware & Electrical Specifications
‑ Manufacturer: Bently Nevada (Baker Hughes) ‑ Device Type: Rack Power Supply Module for 3300 series monitoring rack ‑ Input Power Range: DC 20‑34 Vdc nominal 26 Vdc; or AC 90‑140 Vdc nominal 120 Vdc ‑ Output: Multiple regulated DC output rails for rack backplane and transducer power ‑ Maximum Load Capacity: Supports full rack configuration with up to 12 monitor modules ‑ Protection Features: Over‑voltage, under‑voltage, reverse‑polarity, over‑current, short‑circuit protection ‑ Mounting: Slot‑mount installation at dedicated power slot of 3300 rack chassis ‑ Mechanical Dimension: 263 mm × 58 mm × 28 mm ‑ Weight: Approx 4.3 kg ‑ Cooling: Convection air cooling, no built‑in fan ‑ PCB Treatment: Conformal coated printed‑circuit board ‑ Operating Temperature: 0 ℃ ~ +65 ℃ ‑ Storage Temperature: ‑40 ℃ ~ +85 ℃ ‑ Certifications: CE, CSA hazardous‑area approvals
Environmental Specifications
‑ Relative Humidity: 5%‑95 %, non‑condensing ‑ Vibration Resistance: Complies with industrial cabinet vibration requirements ‑ Heat Dissipation: Requires sufficient cabinet ventilation to avoid over‑temperature derating
Core Functions
- System central power conversion: Accepts either DC or AC field input power and generates stable multi‑channel regulated DC power for all monitor modules and proximitor transducers in the 3300 rack.
- Full‑rack load driving: Capable of supplying power for maximum 12 monitor modules in one complete 3300 rack frame.
- Multi‑layer fault protection: Shuts down output automatically under over‑voltage, under‑voltage, reverse‑polarity and over‑current conditions to prevent secondary damage to downstream monitor boards. Output recovers automatically once input condition returns to valid operating window.
- System health status indication: Provides power‑ok status signal to rack logic for system diagnostic reporting.
Installation, Replacement & Critical Warnings
- This power module is non‑hot‑swappable. Disconnect main input power before inserting or removing the module.
- Compatibility warning: ‑ Designed exclusively for 3300 series rack dedicated power slot; cannot be applied to 3500 rack hardware. ‑ Select correct input power type (DC or AC) according to site power source; incorrect input selection will permanently damage the unit. ‑ Ensure cabinet ventilation clearance, avoid surrounding high‑heat components; over‑temperature will trigger power‑supply shutdown. ‑ Inspect backplane connector pins for bending, debris and corrosion before module insertion. ‑ Input power wiring shall adopt adequate wire gauge and proper terminal torque to prevent over‑heating at terminals.
- After replacement commissioning and verification: ‑ Apply rated input power and confirm power‑ok status indicator is active. ‑ Verify all rack monitor modules power up without hardware fault alarms. ‑ Check each measurement channel returns valid readings without dropout. ‑ Simulate input power deviation, confirm protection function responds as designed.






-300x300.jpg)
Reviews
There are no reviews yet.