Hardware & Electrical Specifications
‑ Manufacturer: Bently Nevada (Baker Hughes) ‑ Compatible System: FieldMonitor 1701 series machinery monitoring system ‑ Functional Type: FieldMonitor Rack Power Supply Module ‑ Input: 18‑36 VDC wide‑range DC input ‑ Output: Regulated 24 VDC, continuous 1.25 A ‑ Inrush Current: 30 A peak nominal ‑ Internal Fuse: 3 A, 250 VDC ‑ Protection: OVP over‑voltage, reverse‑polarity, short‑circuit fold‑back protection ‑ Indicators: Front‑panel OK green LED for power‑good diagnostic status ‑ Connectors: Module edge‑connector mates with 1701/05 / 1701/06 baseplate backplane ‑ Mounting: Plug‑in slot installation on FieldMonitor terminal base ‑ Cooling: Passive heat‑sink natural convection ‑ Hot‑swap: Non‑hot‑swappable; de‑energize input DC power before replacement ‑ PCB Finish: Conformal coated for harsh power‑plant cabinet environments
Environmental Specifications
‑ Operating Temperature: ‑30 °C ~ +70 °C, output derating above 60 °C ‑ Storage Temperature: ‑40 °C ~ +85 °C ‑ Relative Humidity: 5%‑95 % non‑condensing ‑ Vibration & Shock: Complies with rotating‑machinery cabinet EMI and transient requirements
Mechanical Data
‑ Dimensions (W × H × D): 100 mm ×140 mm ×50 mm ‑ Weight: approx 0.59 kg
Core Functions
- FieldMonitor rack power feed: Delivers stable regulated 24 VDC logic and transducer bias power for all FieldMonitor I/O modules on the baseplate.
- Built‑in fault protection: Protects against input over‑voltage, reverse polarity and downstream short‑circuit faults to avoid collateral damage to monitoring modules.
- System health indication: Front‑panel OK LED provides quick visual diagnostic for power‑supply operational status.
- Backplane power distribution: Distributes power via baseplate internal bus to each plugged‑in signal‑monitor module.
- Transducer bias power source: Provides required DC bias voltage for proximity probe transducer channels within FieldMonitor system.
Installation, Replacement & Critical Warnings
- De‑energize 18‑36 VDC primary input power before removing module; non‑hot‑swappable.
- Only use with compatible 1701/05 or 1701/06 FieldMonitor baseplates; wrong baseplate prevents power‑supply seating and operation.
- Verify input DC voltage stays within 18‑36 VDC range; excessive input voltage will destroy internal power‑circuit components.
- After installation, confirm OK LED illuminates; measure 24 VDC backplane output voltage and verify all monitoring modules power‑up normally.
-
Common failure mode: Input‑side electrical surge damage, internal fuse blow. Investigate cabinet DC‑bus transients when entire FieldMonitor rack loses power.