Description
Hardware & Electrical Specifications
‑ Manufacturer: GE General Electric ‑ Compatible System: DC‑300, EX2000 excitation system ‑ Functional Acronym: NTBAN (Terminal Board) ‑ Signal Types Handled: • Differential A‑Quad‑B encoder inputs, tachometer analog inputs • Analog field signals, discrete input signals • 7‑channel relay outputs (Form A / Form C, 120 VAC rating) ‑ Power: Unregulated 24 VDC /125 VAC input; filtered regulated +5 VDC, +15 VDC encoder supplyABB DCS HE… ‑ Connectors: Screw field terminal blocks, multi‑pin ribbon headers to control rack ‑ On‑Board Jumpers: Encoder supply voltage selection (5V /15V). All jumper positions must be exactly duplicated during replacement ‑ Adjustment: 4 onboard potentiometers for analog‑signal scaling ‑ Indicators: LED status for channel fault diagnosis ‑ PCB Finish: Conformal coated multilayer PCB ‑ Compatibility Restriction: For DC‑300 / EX2000; incompatible with Mark‑VI / Mark‑VIe. G1 denotes hardware revision.
Environmental Specifications
‑ Operating Temperature: 0 °C ~ +60 °C ‑ Storage Temperature: −40 °C ~ +85 °C ‑ Relative Humidity: 5%‑95% non‑condensing ‑ Installation Environment: Drive‑excitation cabinet interior, Pollution Degree 2 ‑ EMC: Designed for power‑plant cabinet EMI and switching‑transient conditions
Mechanical Data
‑ Mounting: Rack‑mount terminal board ‑ Weight: approx 0.5 kg
Core Functions
- Field‑wiring interface: Terminal interface for encoder, tachometer, analog and discrete field wiring.
- Encoder power conditioning: Filtered +5 V / +15 V configurable power supply for shaft encoder devices.
- Relay output drive: On‑board relay contacts for alarm, trip and auxiliary drive‑system outputs.
- Analog signal scaling: Potentiometer adjustments calibrate tachometer and analog‑input signal ranges.
- On‑board diagnostics: LED indicators assist commissioning and troubleshooting field‑signal faults.
Installation, Replacement & Critical Warnings
- Complete system power‑down and lock‑out procedure required before servicing. Non‑hot‑swappable. ESD wrist‑strap protection is mandatory for PCB handling.
- Record jumper positions and potentiometer settings before removal. Wrong encoder‑voltage jumper will destroy field encoder hardware.
- Secure field terminals and ribbon‑cable connections firmly; loose connections cause intermittent encoder loss and drive trips.
- After power‑on, perform signal‑loop verification: check LED status, confirm encoder power level and analog‑input scaling.
-
Common failure mode: Field‑wiring surge damages input circuits; relay‑contact wear for alarm‑output channels. Inspect field wiring when encoder or signal‑read anomalies occur.