GE IC660BBD022 Genius 24VDC Source‑Type Configurable Discrete I/O Block

IC660BBD022 is intelligent distributed discrete I/O block for GE Fanuc Genius field‑bus system. It provides 16 software‑configurable DC discrete circuits, each channel can be independently set as sink‑type digital input, tristate input or source‑type MOSFET output. It draws operating power from field 24 VDC loop, no separate auxiliary power supply required. It operates as Genius‑DP slave station, communicates with Genius‑master PLC via Genius shielded bus cable. Supports input filter time setting, output power‑up default value, pulse test function, and configurable fail‑safe mode upon bus communication loss. Electronic unit and terminal base are separable, field wiring can remain untouched during electronics replacement. Product status: Obsolete, spare‑part only supply available。

Email:2735429704@qq.com
Phone:+86 19316626421

Description

Hardware & Electrical Specifications

‑ Model:IC660BBD022 ‑ Part Number:IC660BBD022 ‑ Module Type:Genius 24VDC Source Configurable Discrete I/O Block ‑ Mounting:Panel or DIN‑rail mounting, standalone Genius field block ‑ Field operating power:18‑30 VDC nominal 24 VDC, max block consumption 300 mA, hold‑up time ≥10 ms ‑ I/O channels:16 independent configurable discrete circuits  • Input mode(sink): Logic ON ≥15 VDC; Logic OFF ≤5 VDC, typical input current 7.8 mA @24VDC; software filter: 5/10/20/50/100 ms selectable; basic response time 1.7 ms  • Output mode(source MOSFET): Per‑channel continuous 2 A, surge 10 A /10 ms; total block max 16 A combined load; ON‑delay ≤1 ms, OFF‑delay ≤2 ms ‑ Communication interfaces:Genius‑DP field‑bus terminal port, baud‑rate 38.4k‑153.6 kbaud; rotary address switch 0‑31; supports HHM handheld‑monitor local configuration; daisy‑chain bus topology ‑ Separate assemblies:Electronics unit IC660EBD020; terminal base IC660TBD022 ‑ PCB treatment:Conformal coated for dust‑moisture‑corrosion resistance ‑ On‑board protection:1500 VAC 1‑minute withstand block‑to‑block galvanic isolation; electronic short‑circuit protection, over‑temperature protection, switch‑fault detection, watchdog supervision, comprehensive channel‑level diagnosis ‑ Compatibility note:Cannot run standalone; must match Genius‑bus master controller; full discrete‑loop simulation test mandatory after replacement.

Environmental Specifications

‑ Operating temperature:0 ℃ ~ +60 ℃ ‑ Storage temperature:‑40 ℃ ~ +85 ℃ ‑ Relative humidity:5%‑95% non‑condensing ‑ Installation location:Indoor industrial control cabinet, IP20 protection degree ‑ EMC compliance:IEC 61000‑6‑2 ‑ Certifications:CE, UL Class I Div 2 hazardous‑location certification

Mechanical Data

‑ Weight:approx 1.4 kg ‑ Dimension:229 × 76 × 102 mm ‑ Handling note:ESD‑sensitive circuit; anti‑static wrist‑strap mandatory during handling ‑ Terminal tightening torque:0.6‑1.0 N·m

Main Functions

  1. 16‑channel software‑reconfigurable discrete points, each channel can be set as digital input or source‑type output, flexible for mixed DI/DO field‑side signal requirements.
  2. Collect status signals from field limit switches, proximity sensors and auxiliary contacts; drive DC solenoid valves, relays and indicator lamps.
  3. Supports input digital filtering, output power‑on default state, pulse test function; configurable fail‑safe: hold last output value or preset fixed value when Genius‑bus communication fails.
  4. Rich built‑in diagnosis: short‑circuit, over‑temperature, switch‑fault and channel‑loop abnormal detection, upload fault events to Genius‑master controller.
  5. Separable electronics assembly allows swap‑out without disconnecting field wiring, reduces site maintenance downtime.
  6. LED status indication:   ‑ Green UNIT OK:Block power‑on and self‑test pass   ‑ Green I/O ENABLED:Genius‑bus communication normal   ‑ 16 individual channel LEDs:Real‑time status for each I/O circuit

Installation & Wiring Requirements

  1. Cut off field 24 VDC power before replacement. Hot‑swap is forbidden. Strict anti‑static protection when handling block.
  2. Securely mount block on panel or DIN‑rail; set rotary Genius‑bus address switch consistent with master configuration.
  3. Field‑loop and Genius‑bus wiring strictly follow GE Genius hardware manual; use shielded twisted‑pair cable; install bus terminator at physical two ends of Genius trunk; separate signal cables from high‑power power cables; connect shielding to dedicated protective ground terminal.
  4. Complete protective grounding according to GE system specification.
  5. After replacement: power‑on, verify UNIT OK & I/O ENABLED LED status; download block configuration; perform full‑channel trigger test and fault‑simulation test.
  6. Replacement note: Verify Genius‑master firmware compatibility; full discrete‑loop simulation test mandatory before unit put‑into‑service.