Hardware & Electrical Specifications
‑ Model:IC687BEM713B ‑ Part Number:IC687BEM713B ‑ Module Type:Series‑90‑70 Genius Bus Expansion Memory Module ‑ Mounting:Plug‑in into Series‑90‑70 PLC CPU backplane slot ‑ Backplane power:5 VDC from rack backplane, typical consumption 650 mA ‑ Dual‑port RAM:128 KB shared memory for Genius bus data buffering ‑ Cooperated hardware:Must work with Genius bus controller IC687BEM711 ‑ Supported Genius service:Global‑Data broadcast, Datagram message, fault diagnostic data ‑ PCB treatment:Conformal coated for dust‑moisture‑corrosion resistance ‑ On‑board protection:Backplane surge suppression, hardware watchdog, bus error statistics ‑ Compatibility note:Cannot run standalone; must match Series‑90‑70 CPU and IC687BEM711 controller; verify PLC firmware version; full Genius‑bus simulation test mandatory after replacement。
Environmental Specifications
‑ Operating temperature:0 ℃ ~ +60 ℃ ‑ Storage temperature:‑40 ℃ ~ +85 ℃ ‑ Relative humidity:5%‑95% non‑condensing ‑ Installation location:Indoor industrial control cabinet ‑ EMC compliance:IEC 61000‑6‑2 ‑ Certifications:CE, UL Class I Div 2 hazardous‑location certification
Mechanical Data
‑ Weight:approx 0.42 kg ‑ Dimension:Series‑90‑70 standard single‑slot plug‑in module form‑factor ‑ Handling note:ESD‑sensitive high‑speed memory circuit, anti‑static wrist‑strap mandatory during handling ‑ Terminal tightening torque:0.6‑1.0 N·m
Main Functions
- Provide large‑capacity dual‑port buffer memory for Genius bus controller IC687BEM711, enhance data exchange capacity between Series‑90‑70 CPU and Genius remote I/O blocks.
- Cache cyclic global‑data, acyclic datagram messages and slave block fault diagnostic information, reduce CPU load of processing Genius bus data.
- Revision‑B hardware is backward‑compatible, can directly replace IC687BEM713A without hardware modification.
- LED status indication: ‑ Green OK:Module power‑on and self‑test pass ‑ ACT:Genius‑bus data access activity indicator
Installation & Wiring Requirements
- Cut off Series‑90‑70 PLC rack power before replacement. Hot‑swap is forbidden. Strict anti‑static protection when handling module.
- Insert IC687BEM713B fully into PLC backplane slot and lock latch; confirm matching with IC687BEM711 Genius controller module.
- Genius‑bus wiring strictly follow GE Genius hardware manual; use shielded twisted‑pair bus cable; install terminating resistor at both physical ends of bus trunk; separate signal cables from high‑power cables, connect shielding to dedicated protective ground terminal.
- Complete protective grounding according to GE system specification.
- After replacement:power‑on PLC, verify OK & ACT LED status, download Genius hardware configuration, perform bus‑scan and full I/O‑loop commissioning test.
- Replacement note: Verify CPU firmware compatibility; full Genius‑bus‑loop simulation test mandatory before unit put‑into‑service.