Hardware Specifications

  • Processor: Intel 80386EX, 25 MHz, firmware‑supported floating‑point math
  • User Memory: 240 KB configurable RAM / Flash memoryMoore Auto…
  • I/O Capacity: Max 2048 discrete inputs / 2048 discrete outputs; up to 32640 analog words
  • Scan Speed: ~0.22 ms per 1K boolean logic contactsMoore Auto…
  • Communication: Built‑in 10Base‑T Ethernet; power‑supply‑mounted SNP/SNPX slave serial port; Genius bus compatible
  • Power Draw: 5 VDC, 1100 mA, single‑slot backplane installationMoore Auto…
  • Operating Temperature: 0 °C ~ 60 °C
  • Expansion: 1 main baseplate plus up to 7 expansion / remote I/O baseplates (total 8 racks)Moore Auto…
  • Programming Software: Proficy Machine Edition, VersaPro

Core Functions

  • Execute ladder‑logic and function‑block programs with watchdog fault supervision.
  • Support PID control, high‑speed counter, timer‑counter, shift‑register and periodic interrupt subroutines.
  • Ethernet for program download, HMI connection and peer‑to‑peer PLC data exchange.
  • Native Genius bus interface for distributed Genius I/O network deployment.
  • On‑board system diagnostics, fault logging, battery‑backed RAM for program and data retention during power loss.

Installation Requirements

  • Insert into dedicated CPU slot of Series 90‑30 main baseplate.
  • Verify rack power‑supply can deliver sufficient 5 VDC current for CPU and other modules.
  • Install IC693ACC302 lithium backup‑battery module to preserve data on power‑off.
  • Operate within 0‑60℃ ambient, avoid heavy dust, vibration and condensation.
  • Complete hardware configuration before downloading user application program.

Common Fault Modes

  1. CPU fault LED active: watchdog timeout, program execution fault, memory parity error, fatal configuration mismatch.
  2. Unable to enter RUN mode: missing program, hardware configuration mismatch, key‑switch set to STOP state.
  3. Ethernet communication failure: cable defect, wrong IP address setting, firmware incompatibility with partner devices.
  4. Data loss after power cycle: backup‑battery low voltage or defective unit.
  5. Real‑time clock failure: backup‑battery exhaustion, battery replacement required.