GE IC693DNM200-BC Series 90‑30 DeviceNet Master Communication Module

IC693DNM200‑BC is DeviceNet master station communication module for GE Fanuc Series‑90‑30 PLC platform, BC is updated hardware/firmware revision, backward‑compatible with AB version, fixes known firmware bugs of older revisions. It occupies one single‑slot backplane position, independently runs DeviceNet protocol stack without heavy occupation of PLC CPU scan resources. Supports maximum 63 DeviceNet slave nodes per network segment, compatible with DeviceNet remote I/O, inverters, servo drives, sensors and valve terminals. Equipped with removable spring terminal for DeviceNet bus, plus 9‑pin D‑sub RS‑232 service port for local configuration and firmware upgrade. Supports Polled, Strobed, Cyclic, COS(Change‑of‑State) I/O connections and UCMM explicit message, supports mixed master‑slave mode. Configuration software: Proficy Machine Edition. Product status: Obsolete, spare‑part only supply available。

Email:2306444920@qq.com
Phone:+86 17759635229

Description

Hardware & Electrical Specifications

‑ Model:IC693DNM200‑BC ‑ Part Number:IC693DNM200‑BC ‑ Module Type:Series‑90‑30 DeviceNet Master Communication Module ‑ Mounting:Plug‑in onto any Series‑90‑30 PLC backplane I/O slot ‑ Backplane power:5 VDC @450 mA drawn from rack backplane ‑ DeviceNet baud‑rate:125 k / 250 k / 500 k baud, software configurable ‑ Max slave nodes:63 slaves per module; each slave supports max 2 I/O connections; total 126 I/O connections maximum ‑ Data buffer capacity:Per‑slave max 255‑byte input / 255‑byte output; global total max 3972‑byte input / 3972‑byte output ‑ Interfaces:  • Removable spring screw terminal:DeviceNet bus connection  • 9‑pin D‑sub female RS‑232 service port:firmware download, local debugging ‑ Supported connection types:Polled, Strobed, Cyclic, COS Change‑of‑State, UCMM explicit messaging, proxy connection per slave ‑ External bus power:DeviceNet bus power 12‑24 VDC supplied externally, not taken from PLC rack ‑ PCB treatment:Conformal coated for dust‑moisture‑corrosion resistance ‑ On‑board protection:Transient surge suppression on DeviceNet bus, hardware watchdog, network & slave diagnostic counter ‑ Compatibility note:Cannot run standalone; match Series‑90‑30 CPU; BC revision can directly replace AB version; DeviceNet trunk cable needs 121Ω terminating resistors at both ends; full DeviceNet network simulation test mandatory after replacement。

Environmental Specifications

‑ Operating temperature:0 ℃ ~ +60 ℃ ‑ Storage temperature:‑40 ℃ ~ +85 ℃ ‑ Relative humidity:5%‑95% non‑condensing ‑ Installation location:Indoor industrial control cabinet, IP20 ‑ EMC compliance:IEC 61000‑6‑2 ‑ Certifications:CE, UL Class I Div 2 hazardous‑location certification

Mechanical Data

‑ Weight:approx 0.34 kg ‑ Dimension:Series‑90‑30 standard single‑slot module form‑factor ‑ Handling note:ESD‑sensitive communication circuit, anti‑static wrist‑strap mandatory during handling; strictly comply with DeviceNet cabling specification

Main Functions

  1. Acts as DeviceNet network master for Series‑90‑30 PLC, manages bus scheduling, realizes bidirectional data exchange between PLC and field‑side DeviceNet slave devices.
  2. Supports multiple I/O connection modes and explicit message, completes real‑time acquisition and control for remote I/O, frequency converters, servo drives, field sensors and valve islands.
  3. Rich network diagnosis function: slave offline alarm, bus error statistics, communication fault status, upload fault information to PLC CPU.
  4. RS‑232 service port supports module firmware upgrade and local debugging without DeviceNet network.
  5. LED status indication on front panel:   ‑ Green OK:Module power‑on and self‑test pass   ‑ NET:DeviceNet network link status indicator   ‑ I/O:Bus I/O data activity indicator   ‑ FAULT:Module / network / slave fault alarm

Installation & Wiring Requirements

  1. Cut off Series‑90‑30 PLC rack power and DeviceNet external bus power before replacement. Hot‑swap is forbidden. Strict anti‑static protection when handling module.
  2. Insert IC693DNM200‑BC fully into PLC backplane slot and lock latch.
  3. DeviceNet field wiring strictly follow ODVA DeviceNet specification and GE hardware manual; use certified DeviceNet shielded cable; install 121Ω terminating resistor at both physical ends of trunk cable; separate bus cable from high‑power cables, connect shielding to protective ground terminal.
  4. Complete protective grounding according to GE system specification.
  5. After replacement:power‑on PLC and DeviceNet bus power; verify OK / NET / FAULT LED status; download DeviceNet hardware configuration; perform network scan, slave identification and full I/O communication test.
  6. Replacement note: Verify CPU firmware compatibility; BC revision fixes partial known bugs of AB version; confirm baud‑rate match and terminating resistor installation; full DeviceNet network commissioning test mandatory before unit put‑into‑service.