IC695CPE310 is mid‑range embedded CPU controller for GE PACSystems RX3i platform, install on RX3i universal dual‑bus backplane. Equipped with built‑in 10/100M Ethernet, RS‑232, RS‑485 and USB‑Host interface. 10MB non‑volatile flash memory, program/data no‑battery retention. Optional IC695ACC400 energy pack for power‑loss instant data saving to non‑volatile storage. Supports IEC61131‑3 programming languages: Ladder Diagram, Structured Text, FBD, plus C‑language. Compatible with IC695 / IC694 / legacy IC693 Series‑90‑30 I/O modules. Supports up to 8 expansion racks, max 32K discrete I/O, 32K analog registers. Firmware upgradable via USB flash drive. Configuration software: Proficy Machine Edition. Product status: Obsolete, spare‑part only supply available。

Email:2735429704@qq.com
Phone:+86 19316626421

Description

Hardware & Electrical Specifications

‑ Model:IC695CPE310 ‑ Part Number:IC695CPE310 ‑ Module Type:RX3i Mid‑range CPU Controller Module ‑ Mounting:Plug‑in any slot of RX3i universal backplane (IC695CHS series) ‑ Backplane power consumption:  • +3.3VDC:1000 mA  • +5VDC:1000 mA (max 1500 mA when USB fully loaded) ‑ User memory:  • Program & data flash memory:10 MB non‑volatile, no‑battery retain ‑ Logic execution speed:0.072 ms / 1000 boolean instructions ‑ I/O capacity:  • Discrete %I / %Q:32K bits  • Analog %AI / %AQ:32K words each ‑ Built‑in communication interfaces:  • Ethernet:10/100 Base‑TX RJ45, support EGD, SNP, Modbus‑TCP, max 2 programming connections  • COM1:RS‑232, SNP‑Slave, Modbus‑RTU slave  • COM2:RS‑485 half‑duplex, Modbus‑RTU master/slave, SNP‑Slave  • USB‑Host Type‑A:for firmware upgrade, program backup/restore via USB disk ‑ RTC real‑time clock:max drift 2 seconds per day; backup battery typical service life 5‑years ‑ Expansion capacity:max 8 local expansion racks ‑ Optional accessory:IC695ACC400 Energy Pack (power‑loss emergency power for NVS write) ‑ Diagnostics:CPU self‑diagnosis, backplane bus fault, I/O fault, memory check, Ethernet port status ‑ PCB treatment:Conformal coated for dust‑moisture‑corrosion resistance ‑ Compatibility note:Cannot run standalone; must match RX3i universal backplane; backward compatible with most Series‑90‑30 I/O modules; full system download & I/O mapping test mandatory after replacement。

Environmental Specifications

‑ Operating temperature:0 ℃ ~ +60 ℃ ‑ Storage temperature:‑40 ℃ ~ +85 ℃ ‑ Relative humidity:5%‑95% non‑condensing ‑ Installation location:Indoor cabinet, IP20 ‑ EMC compliance:IEC 61000‑6‑2 ‑ Certifications:CE, UL Class I Div 2 hazardous‑location certification

Mechanical Data

‑ Weight:approx 0.34 kg ‑ Dimension:RX3i single‑slot CPU module form‑factor ‑ Handling note:ESD‑sensitive high‑speed processor circuit; RTC battery needs periodic replacement; USB port only for storage‑device, not for PC direct programming

Main Functions

  1. Main control core of RX3i system, execute user logic program, process analog calculation, floating‑point arithmetic, complete logic control for local and expansion‑rack I/O modules via dual PCI/serial backplane bus.
  2. Multiple built‑in communication ports: Ethernet for programming, SCADA, Modbus‑TCP; RS‑232/RS‑485 for Modbus‑RTU instrument & multi‑PLC communication.
  3. USB‑Host supports program backup, restore and field firmware upgrade without programming computer.
  4. Without battery for program/data retention; RTC clock relies on internal battery; energy pack option realizes power‑loss automatic save to non‑volatile storage.
  5. LED status indication on front panel:   ‑ Green CPU OK:CPU hardware & run status normal   ‑ Red FAULT:CPU hardware / memory / configuration fault   ‑ Green RUN:Program running state   ‑ I/O FORCE:I/O force‑on active indicator   ‑ Ethernet / COM1 / COM2:Communication activity LED

Installation & Wiring Requirements

  1. Cut off rack power before replacement. Hot‑swap is forbidden for CPU module. Strict anti‑static protection when handling CPU module.
  2. Insert IC695CPE310 fully into RX3i universal backplane slot and lock latch; install optional IC695ACC400 energy pack if required.
  3. Network & serial wiring strictly follow GE RX3i hardware manual; use shielded twisted‑pair for RS485 bus; install terminating resistor at bus end; reliable protective‑ground connection.
  4. After replacement:power‑on rack; verify CPU OK / RUN / FAULT LED status; download hardware configuration and user program; complete I/O mapping, communication link test.
  5. Replacement note: Check RTC battery aging status; confirm total backplane power‑supply load capacity; full‑system commissioning test mandatory before unit put‑into‑service。