GE IC697MDL750E Series 90‑70 32‑Point 24/48VDC Sinking Discrete Output Module

IC697MDL750E is engineering revision E hardware version of IC697MDL750 discrete output module for GE Fanuc Series 90‑70 PLC platform. It provides 32 sinking‑type DC output channels divided into four electrically isolated groups of eight points each. Nominal operating voltage is 24 VDC or 48 VDC with operating output voltage range from 20 VDC to 60 VDC. Each channel drives solenoid valves, indicator lamps, relay coils and small inductive actuators.

Revision‑E incorporates internal component and PCB layout improvements for enhanced surge‑withstand capability and long‑term reliability compared to earlier hardware revisions (A‑D). It supports high inrush‑current handling for inductive loads, 10 A peak for 20 ms pulse duration. Output turn‑on / turn‑off response time is maximum 1 ms. Galvanic isolation exists between field output circuits and PLC backplane, partial isolation between output groups. Termination requires IC697TBB007 terminal‑block accessory. Configuration is performed via Logicmaster 90‑70 or Proficy Machine Edition software. Reference manual GFK‑0085H. Product status: Obsolete, spare‑part supply only. Not compatible with RX3i backplane; hot‑swap is not

Email:2735429704@qq.com
Phone:+86 19316626421

Description

Hardware & Electrical Specifications

‑ Model: IC697MDL750E ‑ Part Number: IC697MDL750E ‑ Module Type: Series 90‑70 Discrete Output Module, occupies one slot on Series 90‑70 backplane ‑ Mounting: Series 90‑70 main rack or remote expansion rack ‑ Backplane power consumption:  • +5 VDC: 250 mA maximum ‑ Output channels: 32 points, 4 isolated groups × 8 points ‑ Nominal field voltage: 24 VDC / 48 VDC ‑ Output operating range: 20 VDC ~ 60 VDC ‑ Per‑point output current: 0.5 A maximum per channel ‑ Maximum group current: 2 A per group ‑ Inrush withstand: 10 A peak for 20 ms for inductive‑load surge ‑ Output voltage drop: Max 1 V at rated load ‑ Off‑state leakage current: ≤ 1 mA ‑ Response time: Turn‑on ≤ 1 ms, Turn‑off ≤ 1 ms ‑ Isolation rating: 1500 V between field output and backplane; 500 V between output groups ‑ Termination accessory: IC697TBB007 terminal block ‑ Diagnostics: Module self‑test; group‑level over‑current fault reporting to Series‑90‑70 CPU; no individual channel fuse ‑ PCB treatment: Conformal coated for dust, moisture and corrosion resistance; Revision‑E hardware layout optimization for improved surge robustness ‑ Compatibility note: Functionally drop‑in replacement for earlier‑revision IC697MDL750 (A‑D). Works with all Series 90‑70 CPUs, usable in local racks and BEM731 / BEM733 remote racks. Hot‑swap prohibited. After replacement, verify group power‑supply wiring, download hardware configuration, validate output action for all channels.

Environmental Specifications

‑ Operating temperature: 0 ℃ ~ +60 ℃ ‑ Storage temperature: −40 ℃ ~ +85 ℃ ‑ Relative humidity: 5%‑95% non‑condensing ‑ Installation location: Indoor control cabinet, IP20 protection class ‑ EMC compliance: IEC 61000‑6‑2 ‑ Certifications: CE, UL Class I Div 2 hazardous‑location certification

Mechanical Data

‑ Weight: approx 0.32 kg ‑ Dimension: Series 90‑70 standard single‑slot module form‑factor

Main Functions

  1. Converts PLC backplane logic commands into field‑side 24/48 VDC sinking switching signals to drive solenoids, pilot lamps, relay coils and other DC actuators. High‑density 32‑point design optimizes rack slot utilization. Revision‑E hardware improves resistance against inductive‑load transients.
  2. Built‑in surge‑withstand capability handles inrush current of inductive loads. Group‑level over‑current protection prevents module damage under field short‑circuit conditions.
  3. Front‑panel LED indicators:   ‑ Individual channel LED: Illuminates when corresponding output channel is ON state.

Installation & Wiring Requirements

  1. Cut off full rack power supply before installation or replacement. Hot‑swap is not permitted. Apply ESD protection during module handling.
  2. Insert IC697MDL750E into free slot of Series 90‑70 backplane and fasten module latch. Install matching IC697TBB007 terminal‑block assembly.
  3. Field wiring comply with manual GFK‑0085H. Connect proper DC power supply to each output‑group common terminals. For inductive loads, install free‑wheel diode across each load coil to suppress voltage spike. Keep output cables separated from high‑voltage power cables. Reliable protective‑ground connection is mandatory.
  4. After replacement: Power‑on rack power. Download hardware configuration. Toggle each output bit from PLC software and verify channel LED status and actual field‑load operation. Simulate group over‑current condition to check fault‑reporting behavior.
  5. Replacement note: Each output‑group requires independent field power supply; incorrect common‑power wiring will cause entire‑group output failure. Full‑system commissioning test is mandatory before putting into service.