Description
Hardware & Electrical Specifications
- Model:IS200DTAIH1ACC
- Part Number:IS200DTAIH1ACC
- Module Type:Simplex Analog‑Input‑Output Terminal Board
- Mounting:Plastic bracket, DIN‑rail installation inside turbine control cabinet
- Power supply:Auxiliary 24 V DC supplied by system rack
- Analog Input:10 channels, configurable 0‑10 V / 4‑20 mA via jumper setting
- Analog Output:2‑channel 0‑20 mA standard output; one channel supports jumper‑modification to 0‑200 mA
- Connector:JR1 37‑pin locking connector (interconnect with I/O core board via ribbon cable)
- Terminal block:TB1 48‑position screw terminals; terminal 43‑44 assigned for SCOM signal common ground
- Jumper resources:Total 21 groups jumper switches for channel signal‑mode configuration
- PCB treatment:Conformal coated for dust‑moisture‑corrosion resistance
- On‑board protection:ESD protection, surge suppression, RC filter circuit for field signal loop
- Compatibility note:Cannot run standalone; must pair with corresponding Mark VI analog I/O core board; pin‑to‑pin compatible with IS200DTAIH1ABB, but jumper configuration must be fully restored after replacement to avoid signal fault or hardware damage。
Environmental Specifications
- Operating temperature:‑30 ℃ ~ +65 ℃
- Storage temperature:‑40 ℃ ~ +85 ℃
- Relative humidity:5%‑95% non‑condensing
- Installation location:Indoor turbine control cabinet
- EMC compliance:IEC 61000‑6‑2
- Certifications:CE
Mechanical Data
- Weight:approx 1.20 kg
- Dimension:200 mm × 145 mm × 55 mm
- Handling note:ESD‑sensitive printed circuit board, anti‑static wrist‑strap operation mandatory
- Recommended wire cross‑section:0.75‑2.5 mm² shielded twisted‑pair copper cable for field‑side signal wiring
- Terminal tightening torque:0.6‑1.0 N·m
Main Functions
- Terminate field analog signals from pressure, flow and other process transmitters via screw terminals.
- Route field analog‑input signals to matched I/O core board through 37‑pin ribbon‑cable connection.
- Convert analog output signals from controller board into field‑side current‑type control signals for actuators.
- On‑board jumpers configure each channel for voltage‑mode or current‑mode according to site field‑device type.
- Provide dedicated SCOM common‑ground terminals for field‑cable shielding connection.
- Built‑in filter and surge‑suppression circuit to improve anti‑interference performance for long‑distance field wiring.
- On‑board hardware channel diagnosis for over‑range, short‑circuit fault detection.
- LED status indication:
- Green LED:Terminal‑board auxiliary power supply normal
- Yellow LED:Signal‑channel active status
- Red LED:Field‑channel short‑circuit / over‑range fault alarm
Installation & Wiring Requirements
- Cut off rack power supply before replacement. Hot‑swap is forbidden. Must perform anti‑static protection when handling PCB assembly.
- Secure plastic DIN‑rail bracket firmly; ensure JR1 37‑pin connector fully locked without loose contact.
- Restore on‑board jumper configuration strictly consistent with original settings before connecting field wiring.
- Field wiring uses shielded twisted‑pair cables; separate analog signal cables from high‑power cables to reduce electromagnetic interference; connect shield to SCOM terminal with shortest wire length.
- Complete protective grounding according to GE Mark VI Speedtronic system specification.
- After replacement: double‑check jumper positions, verify each AI/AO channel value, confirm no short‑circuit fault before commissioning.
- Replacement note: Hardware pin‑to‑pin compatible with IS200DTAIH1ABB, but jumper setting must be reproduced; full‑channel function test is mandatory after swap.