Description
Hardware & Electrical Specifications
- Model:IS200DTAOH1ABA
- Part Number:IS200DTAOH1ABA
- Module Type:Simplex Analog‑Output Terminal Board
- Mounting:Plastic bracket, DIN‑rail installation inside turbine control cabinet
- Power supply:Auxiliary 24 V DC from system rack
- Analog Output:8 channels, configurable 0‑10 V / 4‑20 mA via on‑board jumpers
- Connector:JR1 37‑pin locking connector (interconnect with analog‑output core board via ribbon cable)
- Terminal block:TB1 screw‑type field‑wiring terminals, dedicated SCOM signal common‑ground terminals
- Jumper resources:Multiple groups of jumper switches for each channel signal‑mode selection
- PCB treatment:Conformal coated for dust‑moisture‑corrosion resistance
- On‑board protection:ESD protection, surge suppression, RC filter circuit for field output loop
- Compatibility note:Cannot run standalone; must pair with corresponding Mark VI analog‑output core controller board; jumper configuration must be fully restored after replacement to avoid output abnormality or hardware damage。
Environmental Specifications
- Operating temperature:‑30 ℃ ~ +65 ℃
- Storage temperature:‑40 ℃ ~ +85 ℃
- Relative humidity:5%‑95% non‑condensing
- Installation location:Indoor turbine control cabinet
- EMC compliance:IEC 61000‑6‑2
- Certifications:CE
Mechanical Data
- Weight:approx 1.15 kg
- Dimension:200 mm × 145 mm × 55 mm
- Handling note:ESD‑sensitive printed circuit board, anti‑static wrist‑strap operation mandatory
- Recommended wire cross‑section:0.75‑2.5 mm² shielded twisted‑pair copper cable for field‑side signal wiring
- Terminal tightening torque:0.6‑1.0 N·m
Main Functions
- Receive analog‑output control signals from Mark VI I/O core board via 37‑pin ribbon‑cable interface.
- Route and condition analog regulating signals, output 4‑20 mA / 0‑10 V signals to field actuators, valve positioners and I/P converters.
- On‑board jumpers configure each output channel for voltage‑mode or current‑mode according to site field‑device requirement.
- Provide dedicated SCOM common‑ground terminals for field cable shielding connection.
- Built‑in filter and surge‑suppression circuit to improve anti‑interference performance for long‑distance field wiring.
- Hardware channel diagnosis: detect output loop open‑circuit, short‑circuit fault, report fault status to controller.
- LED status indication:
- Green LED:Terminal‑board auxiliary power supply normal
- Yellow LED:Output‑channel active status
- Red LED:Field‑loop short‑circuit / open‑circuit fault alarm
Installation & Wiring Requirements
- Cut off rack power supply before replacement. Hot‑swap is forbidden. Must perform anti‑static protection when handling PCB assembly.
- Secure plastic DIN‑rail bracket firmly; ensure JR1 37‑pin connector fully locked without loose contact.
- Restore on‑board jumper configuration strictly consistent with original settings before connecting field wiring.
- Field wiring uses shielded twisted‑pair cables; separate analog signal cables from high‑power cables to reduce electromagnetic interference; connect shield to SCOM terminal with shortest wire length.
- Complete protective grounding according to GE Mark VI Speedtronic system specification.
- After replacement: double‑check jumper positions, verify each AO channel output value, confirm no short‑circuit fault before commissioning.
- Replacement note: Jumper setting must be reproduced exactly as original; full‑channel output function test is mandatory after swap.