Description
Hardware & Electrical Specifications
- Model:IS200SRTDH2ACB
- Part Number:IS200SRTDH2ACB
- Module Type:SRTD Simplex RTD Terminal Board
- Mounting:DIN‑rail bracket installation inside turbine control cabinet
- Power supply:+24 V DC auxiliary power supplied by matching I/O pack, typical current 0.3A
- Input channels:8‑channel RTD input, configurable for 2‑wire /3‑wire sensor mode by on‑board jumpers
- Supported sensor:PT100, PT1000 resistance temperature detector
- Galvanic isolation:2500V RMS channel‑to‑ground isolation rating
- Interface:Screw terminal blocks for field RTD wiring; dual high‑density IDC ribbon‑cable connectors connecting to PRTD I/O pack
- PCB treatment:Conformal coated for dust‑moisture‑corrosion resistanceAX Control…
- On‑board protection:ESD protection, surge suppression, RC EMI filter circuit for temperature signal loop
- Compatibility note:Cannot run standalone; must match PRTD RTD I/O pack; jumper wiring‑mode setting must restore after replacement; full‑channel temperature calibration test required after replacement.
Environmental Specifications
- Operating temperature:‑40 ℃ ~ +70 ℃
- Storage temperature:‑40 ℃ ~ +85 ℃
- Relative humidity:5%‑95% non‑condensing
- Installation location:Indoor turbine control cabinet
- EMC compliance:IEC 61000‑6‑2
- Certifications:CE
Mechanical Data
- Weight:approx 0.45 kg
- Dimension:178 mm × 159 mm × 45 mm
- Handling note:ESD‑sensitive PCB, anti‑static wrist‑strap mandatory during handling
- Recommended wire cross‑section:0.75‑2.5 mm² shielded twisted‑pair copper cable for RTD sensor wiring
- Terminal tightening torque:0.6‑1.0 N·m
Main Functions
- Screw‑terminal field termination for turbine RTD temperature sensors: bearing metal temperature, winding temperature, exhaust temperature, lube‑oil temperature signals.
- Support 2‑wire /3‑wire RTD sensor configuration, suppress lead‑wire resistance measuring error.
- Signal filtering and surge protection for long‑distance field wiring under high‑EMI power‑plant environment.
- Transmit conditioned resistance‑value signals to PRTD I/O pack via ribbon‑cable link for temperature conversion calculation.
- On‑board channel self‑diagnosis: detect RTD sensor open‑circuit, short‑circuit fault, report fault status to main controller.
- On‑board self‑diagnosis: detect terminal‑board auxiliary power loss and ribbon‑cable link failure.
- LED status indication:
- Green LED:Terminal‑board auxiliary power normal
- Yellow LED:Ribbon‑cable link communication active
- Red LED:Field‑channel fault / link communication loss alarm
Installation & Wiring Requirements
- Cut off rack power supply before replacement. Hot‑swap is forbidden. Strict anti‑static protection when handling PCB board.
- Secure DIN‑rail mounting bracket firmly; ensure IDC ribbon‑cable connectors fully locked without loose contact.
- Restore on‑board jumper (2‑wire /3‑wire mode) strictly consistent with original configuration before field wiring.
- RTD sensor wiring strictly follow GE Speedtronic wiring manual; temperature signal cables adopt shielded twisted‑pair, separate from high‑power cables; connect shielding to dedicated ground terminal.
- Complete protective grounding according to GE Speedtronic system specification.
- After replacement: verify ribbon‑cable link status, calibrate each temperature channel reading, validate over‑temperature alarm response before commissioning.
- Replacement note: TMR redundant system requires three‑set SRTD channel consistency verification; full‑channel temperature function test mandatory after swap.



-300x300.jpg)