GE IS200TTURH1CCC TTUR Turbine Terminal Board

IS200TTURH1CCC (TTUR‑CCC) is conformal‑coated multi‑function turbine field termination board for GE Speedtronic Mark VI gas‑steam turbine control system. It serves as physical signal interface between PTUR turbine protection processor pack and field‑side devices, including magnetic pickup speed sensors, thermocouple/RTD temperature sensors, pressure transmitters, discrete protection contact signals and flame‑detector return‑path signals. CCC suffix stands for enhanced conformal coating for anti‑corrosion, anti‑moisture performance for harsh turbine‑hall environment. Supports simplex and TMR triple‑modular‑redundant architecture. Important for turbine protection and measurement loop; hardware fault may cause measurement deviation or protection mis‑operation. Product status: Obsolete, spare‑part only supply available。

Email:2735429704@qq.com
Phone:+86 19316626421

Description

Hardware & Electrical Specifications

  • Model:IS200TTURH1CCC
  • Part Number:IS200TTURH1CCC (S1DF00Z)
  • Module Type:TTUR Turbine Terminal Board
  • Mounting:Cabinet panel mounting inside turbine control cabinet
  • Logic power supply:24‑28 VDC supplied by PTUR turbine‑protection processor pack
  • Frequency input:Multi‑channel magnetic‑pickup pulse input for turbine overspeed detection, frequency range 0‑50 kHz
  • Analog input:Multi‑channel thermocouple / RTD temperature inputs; 4‑20 mA analog inputs for pressure and process transmitters
  • Discrete input:Barrier‑type contact inputs for hard‑wired protection interlock signals
  • Flame‑detector signal processing:Flame‑detector return‑path signal conditioning circuit
  • Isolation:High galvanic isolation between field side and control rack side, suppress plant ground‑loop interference
  • Interface:Two pluggable barrier‑type screw terminal blocks (24 terminals per block) for field wiring; multiple multi‑pin ribbon‑cable connectors for PTUR processor interconnection; wire gauge up to #12AWG
  • PCB treatment:CCC‑revision enhanced conformal coated for dust‑moisture‑corrosion resistance
  • On‑board protection:ESD protection, MOV surge suppression, over‑voltage and over‑current channel protection, sensor open‑/short‑circuit detection circuit
  • Compatibility note:Cannot run standalone; must match Mark VI PTUR processor pack; full measurement‑loop and protection‑signal simulation test mandatory after replacement。

Environmental Specifications

  • Operating temperature:‑40 ℃ ~ +70 ℃
  • Storage temperature:‑40 ℃ ~ +85 ℃
  • Relative humidity:5%‑95% non‑condensing
  • Installation location:Indoor turbine control cabinet
  • EMC compliance:IEC 61000‑6‑2
  • Certifications:CE

Mechanical Data

  • Weight:approx 1.35 kg
  • Dimension:330 mm × 178 mm × 55 mm
  • Handling note:ESD‑sensitive PCB; multi‑type high‑precision measurement circuit, anti‑static wrist‑strap mandatory during handling
  • Recommended wire cross‑section:0.75‑2.5 mm² shielded twisted‑pair copper cable for speed‑sensor, temperature‑sensor and protection‑contact wiring
  • Terminal tightening torque:0.6‑1.0 N·m

Main Functions

  1. Pluggable barrier screw‑terminal field termination for magnetic‑pickup speed sensors, thermocouple/RTD temperature sensors, pressure transmitters, hard‑wired protection contact signals and flame‑detector return‑path signals.
  2. Condition high‑frequency overspeed pulse signals, thermocouple millivolt weak signals and 4‑20 mA transmitter analog signals, transmit conditioned signals to PTUR turbine‑protection processor pack.
  3. Galvanic isolation between control rack and field‑side devices, suppress turbine‑hall high‑EMI transient interference.
  4. On‑board channel self‑diagnosis: detect magnetic‑pickup open‑circuit / short‑circuit, thermocouple burnout, RTD fault, ribbon‑cable link failure; upload fault alarm to turbine main controller.
  5. LED status indication:
    • Green LED:Board auxiliary power normal
    • Yellow LED:Ribbon‑cable link communication active
    • Red LED:Sensor‑channel fault / link‑failure alarm

Installation & Wiring Requirements

  1. Cut off rack power supply before replacement. Hot‑swap is forbidden. Strict anti‑static protection when handling PCB board.
  2. Secure panel mounting firmly; ensure all multi‑pin ribbon‑cable connectors fully locked without loose contact.
  3. Field‑sensor wiring strictly follow GE Speedtronic Mark VI wiring manual; analog and speed‑signal cables adopt shielded twisted‑pair, strictly separated from high‑power cables; connect shielding to dedicated ground terminal.
  4. Complete protective grounding according to GE Speedtronic system specification.
  5. After replacement: verify ribbon‑cable link status, check speed‑pulse signal quality, verify temperature and analog measurement reading, simulate protection‑contact input condition before commissioning.
  6. Replacement note: For TMR triple‑redundant system application, hardware consistency of related PTUR packs shall be verified; full measurement‑loop and protection‑signal simulation test mandatory before unit put‑into‑service.