Description
Hardware & Electrical Specifications
‑ Model:IS220PAOCH1A ‑ Part Number:IS220PAOCH1A ‑ Module Type:PAO Analog Output Module ‑ Mounting:Installed in Mark VIe I/O pack rack ‑ Power supply:24 VDC field power supplied via I/O pack backplane ‑ Output channels:8 independent isolated current output channels, 0‑20 mA (4‑20 mA configurable), maximum load impedance 900 Ω, output accuracy ±0.5% ‑ On‑board feature:Each channel equipped with current feedback ADC for real‑time output monitoring ‑ Communication interfaces: • Dual redundant IONet RJ45 Ethernet ports for communication with system controller • DC‑37‑pin connector for connection to matching analog output terminal board ‑ Compatible terminal boards:TBAOH1C, STAOH1A, STAOH2A ‑ PCB treatment:Conformal coated for dust‑moisture‑corrosion resistance ‑ On‑board protection:ESD protection, MOV surge suppression, channel galvanic isolation, over‑current / open‑circuit / short‑circuit self‑diagnosis circuit ‑ Compatibility note:Cannot run standalone; must match Mark VIe I/O pack rack and corresponding controller hardware; full signal‑loop simulation test mandatory after replacement.
Environmental Specifications
‑ Operating temperature:‑40 ℃ ~ +70 ℃ ‑ Storage temperature:‑40 ℃ ~ +85 ℃ ‑ Relative humidity:5%‑95% non‑condensing ‑ Installation location:Indoor turbine control cabinet ‑ EMC compliance:IEC 61000‑6‑2 ‑ Certifications:CE
Mechanical Data
‑ Weight:approx 0.38 kghoneywell-… ‑ Dimension:Standard Mark VIe I/O pack module form‑factor ‑ Handling note:ESD‑sensitive PCB; analog output drive circuit, anti‑static wrist‑strap mandatory during handling ‑ Terminal tightening torque:0.6‑1.0 N·m
Main Functions
- Receive digital control set‑point commands from Mark VIe main controller via IONet bus.
- Convert digital values to precise 0‑20 mA / 4‑20 mA analog current output to drive field control valves and actuators.
- Real‑time feedback sampling of each output channel current value, upload actual output status to controller.
- Continuous self‑diagnosis for every output channel, detect open‑circuit, short‑circuit, over‑load and module hardware faults, and report fault alarm status.
- LED status indication: ‑ Green LED:Module power supply normal / RUN status ‑ Yellow LED:Channel signal / IONet link activity indicator ‑ Red LED:Module FAIL / channel fault alarm
Installation & Wiring Requirements
- Cut off I/O pack rack power supply before replacement. Hot‑swap is forbidden. Strict anti‑static protection when handling PCB board.
- Insert module into designated slot of I/O pack rack, lock module latch to ensure reliable backplane contact.
- Field analog output signal wiring strictly follow GE Speedtronic Mark VIe wiring manual; signal cables shall be separated from high‑power cables; connect shielding to dedicated ground terminal.
- Complete protective grounding according to GE system specification.
- After replacement: verify I/O pack power‑on status, check each channel output value, perform analog‑loop commissioning test.
- Replacement note: For TMR triple‑redundant system application, hardware consistency and firmware‑version matching shall be verified; full signal‑loop simulation test mandatory before unit put‑into‑service.