ICS 9852-9802 T9300 TMR Safety Output Channel Package

This matched set includes the 9852 triple redundant digital output card and the 9802 field termination assembly. The pair delivers SIL3-rated on-off safety outputs for industrial safety instrumented systems.

Email:2735429704@qq.com
Phone:+86 19316626421

Description

Specification Breakdown

  • 9852 Card: 8-channel digital output, 24VDC rated. Built-in triple modular redundancy with 2oo3 voting logic. Supports hot-swap within T9300 rack. Continuous diagnostics for wire break, short circuit and load fault. Powered from rack backplane.
  • 9802 FTA: Passive DIN rail mounted termination unit. Equipped with screw terminals for field instrument wiring. Per-channel fuses and surge suppression components are integrated to limit fault energy. Connects to the 9852 card via factory-made ribbon cable.
  • Safety approval: IEC61508 SIL3, FM, CE and UL certifications for safety loop use.
  • Compatible platform: ICS Triplex T9300 TMR SIS. Not interchangeable with classic Tricon v9/v11 or Tricon CX racks.
  • Operating range: -40℃ ~ +70℃; storage -40℃ ~ +85℃; relative humidity 5%–95%, non-condensing
  • Mechanical rating: IP20, for indoor cabinet installation only
  • Wiring rules: Route signal cables separately from high-current power lines. Use shielded twisted pair for field instruments. Apply single-point shield grounding according to project design. Do not cut or splice factory ribbon cables. Power on-site field loops only after full wiring inspection.

Physical Description

The 9852 is a rack plug-in card with a metal front panel populated with multi-color LEDs to show power, channel health and TMR slice faults. Gold plated backplane connectors ensure reliable contact with the rack bus. Three separate redundant circuit boards are fitted internally for fault tolerant signal processing. The 9802 termination assembly is housed in a plastic DIN rail casing, with a green PCB inside. Terminal terminals are clearly labelled for each channel. It has a dedicated multi-pin connector for ribbon cable connection, with no on-board microprocessor.

Industrial Deployment

This combination is widely used in refineries, petrochemical complexes, gas compressor stations, thermal power plants and offshore platforms. It is implemented within ESD emergency shutdown, burner management and turbine protection safety loops. The 9852 receives interlock logic commands from the T9300 controller and outputs 24VDC signals to solenoid valves. The 9802 acts as the intermediate wiring hub; its built-in protective components isolate field side surge and short-circuit faults, preventing permanent damage to the expensive rack I/O card.

Operational & Maintenance Notes

Continuous built-in diagnostics will trigger system alarms for loose terminals, blown fuses, cable breaks or short-circuit events. Anti-static wristbands must be worn when removing or installing either the card or FTA. Always de-energize the relevant 24V field loop before disconnecting wiring or ribbon connectors. Routine site inspection focuses on LED status, terminal screw tightness, cable jacket wear and connector locking clips. Dust accumulation on PCB should be cleaned periodically. After hardware replacement or rewiring, perform point-by-point signal simulation testing on every channel, then check the system diagnostic logs to confirm no unresolved alarms. Maintain spare sets of 9852 and 9802 on site. Replace the whole assembly when PCB traces, terminal pins or internal circuits suffer permanent damage; component-level repair in the field is prohibited.

Fault Analysis Guide

  1. No output response: Check 24VDC field supply, FTA fuse condition, ribbon cable lock status and terminal tightness
  2. Intermittent output dropouts: Investigate shield grounding, cable compression, cabinet vibration and loose terminal connections
  3. Single channel diagnostic fault: Usually caused by blown channel fuse, broken field wire or bent connector pins
  4. System alarms after hardware swap: Confirm compatibility between 9852, 9802 and ribbon cable; verify pin assignment and downloaded system configuration
  5. Repeated fuse blowing: Locate short circuit or overload at solenoid coil or damaged field cable insulation

Reviews

There are no reviews yet.

Be the first to review “ICS 9852-9802 T9300 TMR Safety Output Channel Package”