Description
1. Basic Information
| Item | Content |
|---|---|
| Model | T8160 |
| Series | Trusted T8000 TMR Triple‑Redundant Safety Control System |
| Product Type | TMR Regent Bus Interface Module |
| Safety Certification | IEC61508 SIL3, TÜV certified, 2‑out‑of‑3 voting architecture |
| Installation | Slot‑mount in dedicated Trusted chassis, hot‑swap supported |
| Manufacturer | ICS‑Triplex (Rockwell Automation) |
2. Hardware Specifications
-
Power Supply
‑ Backplane supply: 20‑32 VDC (nominal 24 VDC), dual redundant backplane power; power consumption approx. 22‑28 W
-
Processor & Memory
‑ On‑board independent TMR 3‑channel co‑processor with hardware 2‑out‑of‑3 voting;
‑ On‑board Flash and SDRAM cache for protocol conversion and data mapping between Trusted IMB bus and Regent field bus.
-
Communication Interfaces
‑ Backplane IMB TMR bus: connects to T8110C / T8111C main processor;
‑ External Regent bus interface (RS485 physical layer) for legacy Regent controller rack connection;
‑ Front‑panel LED indicators: Healthy, Active, Standby, Educated, I/O Healthy.
-
Environmental Conditions
‑ Operating temperature: ‑40℃ ~ +70℃;
‑ IP20 (inside cabinet); relative humidity 5‑95% non‑condensing; electrically isolated channels.
3. Key Functions
- TMR Triple‑Modular Redundancy Voting: 3‑channel hardware voting. Single‑channel faults are isolated automatically. Hot‑swap online replacement without disturbing Trusted safety‑logic.
- System Bridging & Protocol Conversion: Acts as gateway for bidirectional data exchange between new‑generation Trusted and legacy Regent controllers, realizes register and I/O point mapping to preserve existing Regent hardware assets.
- Active‑standby Redundancy: Dual T8160 modules support active‑standby hot‑standby with automatic fail‑over upon fault.
- Comprehensive Hardware Self‑diagnosis: Real‑time diagnosis for bus communication and channel status, timestamped fault logging. Front‑panel LEDs indicate module and I/O subsystem status.
- Isolated Data Forwarding: Bus isolation for two systems to prevent fault propagation across systems.
4. Typical Applications
‑ ESD and F&G fire‑gas system retrofit projects in petrochemical & chemical plants
‑ Compatibility upgrade scenarios for legacy safety instrumented systems in oil‑gas and power plants
5. Important Notes
- Firmware version must strictly match T8110C / T8111C processor and Regent‑side firmware. Mismatched firmware will cause bus communication interruption. Verify firmware build number for spare‑part replacement.
- T8160 only works as Trusted‑Regent bridging gateway. It cannot act as CPU and cannot replace T8151B for external DCS/HMI communication.
- Follow RS485 industrial wiring specifications for external Regent bus, implement proper grounding for anti‑interference.
- Compatible only with dedicated Trusted chassis; not applicable for standard PLC racks.