Bently 33103-00-04-10-02-00 3300‑XL 8 mm Proximity Probe

The 330103‑00‑04‑10‑02‑00 is an 8 mm eddy‑current proximity probe of the 3300‑XL series. It forms a complete non‑contact displacement measurement system together with matched extension cable and 3300‑XL proximitor sensor. It measures static axial position and dynamic radial vibration by detecting gap variation between probe tip and conductive shaft target. The probe features M10×1 thread, 40 mm case length and 1‑meter integrated cable with ClickLoc miniature coaxial connector. It delivers high‑precision gap data for rotating‑machinery protection and condition monitoring, complying with API‑670 requirements. The total electrical length of probe‑plus‑extension‑cable must match the proximitor calibrated length to guarantee measurement accuracy. Improper target size, surface material or cable mismatch will degrade linear performance.

Email:2735429704@qq.com
Phone:+86 19316626421

Description

Hardware & Electrical Specifications

‑ Manufacturer: Bently Nevada (Baker Hughes) ‑ Device Type: 3300‑XL 8 mm Eddy‑current Proximity Probe ‑ Probe Tip Diameter: 8 mm ‑ Linear Measurement Range: 2 mm (80 mil) ‑ Nominal Sensitivity: 7.87 V/mm (200 mV/mil), tolerance ±5 % ‑ Thread Specification: M10 × 1 ‑ Case Length: 40 mm ‑ Integrated Probe Cable Length: 1 m ‑ Connector Type: ClickLoc miniature coaxial connector ‑ Probe Tip Material: Polyphenylene sulfide (PPS) ‑ Housing Material: AISI 303 / 304 stainless steel ‑ O‑Ring: Viton sealing ‑ DC Resistance: 7.59 Ω ±0.5 Ω ‑ Frequency Response: DC‑10 kHz (‑3 dB) ‑ Operating Temperature: ‑51 ℃ ~ +177 ℃ ‑ Storage Temperature: ‑55 ℃ ~ +185 ℃ ‑ Minimum Cable Bend Radius: 25.4 mm (1 inch) ‑ Construction: Non‑armored cable ‑ Certifications: CE, CSA, ATEX hazardous‑area approvals

Environmental Specifications

‑ Relative Humidity: 5%‑95 %, non‑condensing ‑ Vibration Resistance: Complies with API‑670 field installation vibration requirements ‑ Chemical Resistance: Resists oil mist, turbine lubricant and common industrial contaminants

Core Functions

  1. Non‑contact gap sensing: Generates high‑frequency eddy‑current field to detect physical clearance between probe tip and metallic shaft target, converts mechanical gap variation into RF signal sent to proximitor.
  2. Radial‑vibration measurement: Captures dynamic shaft radial vibration for turbine, compressor and generator condition monitoring.
  3. Axial‑thrust‑position measurement: Monitors static thrust‑shaft displacement to detect thrust‑bearing wear.
  4. System interchangeability: 3300‑XL components support module‑to‑module interchangeability without individual bench calibration when total system electrical length is maintained.
  5. Harsh‑environment adaptability: High‑temperature probe tip and corrosion‑resistant stainless‑steel housing suit long‑term operation inside turbine casings and cabinet environments.

Installation, Replacement & Critical Warnings

  1. This sensing probe cannot be hot‑swapped. Isolate the measurement channel before probe removal or mounting work.
  2. Compatibility warning: ‑ The total electrical length (probe plus extension cable) shall strictly match the paired 3300‑XL proximitor specification. Do not use extension cables of arbitrary length. ‑ Target surface material must be standard ferrous or non‑ferrous steel; hard coating, plating or small target dimensions will reduce effective linear range. ‑ Mount via M10×1 thread and lock‑nut; control mounting torque to avoid thread damage or probe‑tip deformation. ‑ Recommended operating gap setting: approx 1.27 mm (50 mil), corresponding to proximitor output of about ‑9 Vdc. ‑ Signal cables shall be routed separately from high‑voltage power and variable‑frequency‑drive cables to minimize electromagnetic crosstalk. ‑ Avoid sharp bending, pulling or squeezing the probe cable; excess cable shall be loosely coiled observing minimum bend‑radius limits. ‑ Connector contacts shall be kept clean; inspect for dirt, oil and corrosion before mating.

Commissioning and Verification Criteria

  1. Confirm mechanical mounting: probe is securely locked, tip has safe clearance to rotating target, no mechanical collision risk.
  2. Perform static gap calibration: adjust probe installation gap within valid linear range, verify proximitor output voltage changes linearly with gap movement.
  3. Check raw signal waveform through proximitor BNC test port; waveform shall be stable without excessive noise.
  4. Under machine stand‑still and running conditions, confirm vibration and position readings are stable, without random jumping or drifting.
  5. Simulate probe‑loop open‑circuit / short‑circuit condition to verify system loop‑fault alarm activates correctly.

Common Failure Modes and Symptoms

‑ Probe‑tip damage or contamination: Disturbed eddy‑current field, measurement offset, poor linearity. ‑ Internal cable open / intermittent breakage: Intermittent reading fluctuation, sporadic loop‑fault alarm, signal dropout. ‑ Connector pin corrosion or contamination: Unstable signal transmission, irregular data jitter. ‑ Improper installation gap: Operating point falls outside linear range, vibration measurement loses accuracy. ‑ Incompatible target material or insufficient target area: Sensitivity deviation, measurement error, no hardware fault alarm triggered.