Bently 3500-22M 138607-02 Transient Data Interface Module, TMR Triple‑Modular Redundant Version

138607‑02 is the TMR triple‑modular redundant dedicated old‑generation TDI main board for 3500 TSI rack. It is hardware‑different from standard‑version 138607‑01. Must be installed in fixed Slot‑2 next to power‑supply slots of 3500‑05 rack, one module per TMR rack. Besides all standard TDI functions: rack configuration download, steady‑state / transient waveform data acquisition, communication with 3500 configuration software and System 1 software, it adds TMR channel comparison voting function. Continuously compares measurement values from three groups of redundant monitor cards. If one‑channel data deviates beyond set threshold, it marks fault and generates system event log for triple‑redundant turbine protection rack. It works with rear plug‑in I/O communication card: 146031‑01(copper Ethernet) / 146032‑01(fiber Ethernet), rear I/O card is sold separately. Obsolete and discontinued, no original factory new orders. Cannot inter‑change with standard 138607‑01. Cannot replace later‑generation 288055‑02 without rack firmware upgrade. Not compatible with legacy 3500/20‑125744‑02 RIM.

Email:2306444920@qq.com
Phone:+86 17759635229

Description

Hardware & Electrical Specifications

‑ Manufacturer: Bently Nevada (Baker Hughes) ‑ Compatible System: 3500 series TSI machinery‑protection rack, for TMR triple‑redundant system, matches M‑series monitor cards ‑ Functional Type: Old‑Generation TMR‑version Transient Data Interface TDI Main Board ‑ Install Slot: Fixed Slot‑2 beside power‑supply slots of 3500‑05 rack ‑ Power Consumption: 10.8 W, powered by rack backplane bus ‑ Front‑panel: USB‑B service port, RUN/PROGRAM key switch, rack reset button, multi‑LED status indicator (OK, COMM, FAULT, TMR‑ALARM) ‑ External Communication: Dependent on rear I/O card: 10/100 Base‑TX copper or 100 Base‑FX fiber Ethernet ‑ Hot‑swap: Supports hot‑swap. After hot‑swap, rack hardware protection keeps running; TMR comparison and upper‑computer data transmission are temporarily interrupted. ‑ PCB Coating: Conformal coated for G3 harsh industrial cabinet environment

Environmental Specifications

‑ Operating Temperature: 0 °C ~ +60 °C ‑ Storage Temperature: ‑40 °C ~ +85 °C ‑ Relative Humidity: 5%‑95 % non‑condensing ‑ Vibration & Shock: Complies with API‑670 power‑plant cabinet EMC standards

Mechanical Data

‑ Dimension(W×H×D):25.4 mm ×120.7 mm ×251.5 mm ‑ Weight: approx 0.98 kg

Core Functions

  1. Rack communication gateway: Complete rack parameter download, read module status, alarms and event logs via configuration software.
  2. TMR channel comparison & voting: Real‑time data comparison for three‑way redundant monitor channels; report deviation fault for inconsistent channel, record system events.
  3. Steady‑state & transient waveform acquisition: Collect vibration, displacement, speed steady‑state values; capture high‑resolution dynamic waveform during start‑up, coast‑down and alarm events for mechanical fault diagnosis.
  4. Upper‑level system interconnection: Cooperates with rear Ethernet I/O card to upload data and events to System 1 condition‑monitoring platform.
  5. Rack status supervision: Monitor power‑supply health and module online status, report system‑level faults.
  6. Safety isolation: TDI fault will not block hardware trip output of TMR monitor cards.

Installation, Replacement & Critical Warnings

  1. Supports hot‑swap; protection trip function remains active during replacement, TMR comparison and data communication stop temporarily.
  2. Compatibility warning: ‑ 138607‑02 is dedicated for TMR rack; cannot use standard‑version 138607‑01 for TMR cabinet, TMR comparison function will be missing. ‑ Replaced by later‑generation 288055‑02; must verify rack firmware version before cross‑generation replacement, firmware mismatch leads to abnormal communication. ‑ Cannot directly replace old 3500/20‑125744‑02 RIM, backplane logic definition is different.
  3. Main board 138607‑02 does not contain rear I/O card; copper/fiber I/O card needs separate matching procurement.
  4. After replacement, check OK & TMR‑ALARM LED status, download complete rack configuration, verify Ethernet communication and TMR channel comparison function.
  5. Common failure mode: Ethernet transceiver surge damage, USB port circuit damage, component aging.

Reviews

There are no reviews yet.

Be the first to review “Bently 3500-22M 138607-02 Transient Data Interface Module, TMR Triple‑Modular Redundant Version”

Your email address will not be published. Required fields are marked *